Dear Niu,

                It depends on which part of processing you are referring to, 
i.e. the indexing step or the integration step. In MOSFLM there is no way to 
enforce cell dimensions during indexing, but providing there is an indexing 
solution that has cell dimensions close to the ones you want, you can enforce a 
(slightly) different set of cell dimensions during the integration step. 
Normally other refined parameters will ensure that you still get a good 
prediction of spot positions.

I suspect that this can be done in other programs too.

Without knowing why you want to do this, I cannot comment on whether this is 
the best procedure to follow.

Best wishes,

Andrew



On 18 Nov 2013, at 21:48, Niu Tou <niutou2...@gmail.com> wrote:

> Dear All,
> 
> Does any one know how to strictly fix the cell dimensions during data 
> processing? In HKL2000 there is only a keyword to define the longest vector. 
> In XDS there is a option to input cell parameters, but sometimes the program 
> would not follow the input values
> and switch back to the one it thinks best. Any suggestions will be 
> appreciated. Thanks!
> 
> Best,
> Niu         

Reply via email to