Thank you all. I had forgotten about checking pdb record formats..
Eleanor


It works when you follow the rules!

On 10/04/2011 05:05 PM, Frances C. Bernstein wrote:
I checked back and the 1992 format decscription did not use
columns 77 - 80 for ATOM/HETATM records. But the 1996 document
did use them. I then checked the old Newsletters and the proposed
use of columns 77 - 80 was discussed in April 1995.

Frances

=====================================================
**** Bernstein + Sons
* * Information Systems Consultants
**** 5 Brewster Lane, Bellport, NY 11713-2803
* * ***
**** * Frances C. Bernstein
* *** f...@bernstein-plus-sons.com
*** *
* *** 1-631-286-1339 FAX: 1-631-286-1999
=====================================================

On Tue, 4 Oct 2011, Ian Tickle wrote:


On Tue, Oct 4, 2011 at 4:41 PM, Eleanor Dodson <c...@ysbl.york.ac.uk>
wrote:
OK

So the ATOM TYPE has ZN O C S etc in column 77/78 and the +2 etc in
79/80

Is there any documentation for this?

E


Yes, see:
ftp://ftp.wwpdb.org/pub/pdb/doc/format_descriptions/Format_v33_A4.pdf

Though this has been the format for ATOM/HETATM records ever since I can
remember.

Cheers

-- Ian