Hi,
you should remove the following lines:

SPOT_RANGE=7 18 !First and last data image number for finding spots SPOT_RANGE=20 20 !First and last data image number for finding spots

and instead define the spot range only in one line e.g. SPOT_RANGE=1  50

That should fix your problem I think.

Jürgen

On 11 Jun 2009, at 11:27, Sangeetha Vedula wrote:

I checked:

1. I did name it XDS.INP; no problem there.
2. The path along with file name template is only about 30 characters.
3. No. of files = 156 (DATA_RANGE=1 156)
4. Edited Nx, Ny, Qx, Qy (unless the image header is wrong, which could cause problems, but why does it have a problem with data range?).

I am attaching the file, XDS.INP that I am using. Thank you so much in advance for taking the time.

Regards,

Sangeetha.

On Thu, Jun 11, 2009 at 3:23 AM, Kay Diederichs <kay.diederi...@uni-konstanz.de > wrote:
Sangeetha Vedula schrieb:

Hello all,

Apologies for the non-CCP4 question.

I am trying to process some data collected at X6A in March. I edited the XDS.inp file for ADSC detector. When I try to run xds, however, it gives an error immediately:

!!! ERROR !!! UNDEFINED DATA_RANGE=

I checked the data range and the image path and template I gave. Doesn't appear to be anything wrong. What could be causing the error, though?

Thanks for any input and suggestions!

Sangeetha.

Hello Sangeetha,

please post your XDS.INP for us to check.

Kay
--
Kay Diederichs http://strucbio.biologie.uni- konstanz.de email: kay.diederi...@uni-konstanz.de Tel +49 7531 88 4049 Fax 3183 Fachbereich Biologie, Universitaet Konstanz, Box M647, D-78457 Konstanz

<XDS.INP>

-
Jürgen Bosch
Johns Hopkins Bloomberg School of Public Health
Department of Biochemistry & Molecular Biology
Johns Hopkins Malaria Research Institute
615 North Wolfe Street, W8708
Baltimore, MD 21205
Phone: +1-410-614-4742
Lab:      +1-410-614-4894
Fax:      +1-410-955-3655
http://web.me.com/bosch_lab/

Reply via email to