Ethan - that's odd it works for me (CCP4 6.1.0) unless of course it got
broken recently in 6.1.1:

First an extract from the mtz2various log file:

 * Cell Dimensions : (obsolete - refer to dataset cell dimensions above)

   70.3025   68.7834   93.7125   90.0000   94.1913   90.0000

 *  Resolution Range :

    0.00030    0.24999     (     58.124 -      2.000 A )

 * Sort Order :

      1     2     3     0     0

 * Space group = 'I2' (number     4005)


Then the CIF output:

##########
#        #
#  CELL  #
#        #
##########


_cell.entry_id     junk
_cell.length_a              70.3025
_cell.length_b              68.7834
_cell.length_c              93.7125
_cell.angle_alpha           90.0000
_cell.angle_beta            94.1913
_cell.angle_gamma           90.0000


##############
#            #
#  SYMMETRY  #
#            #
##############


_symmetry.entry_id     junk
_symmetry.Int_Tables_number      4005
_symmetry.space_group_name_H-M     'I 1 2 1'


####################
#                  #
#  SYMMETRY_EQUIV  #
#                  #
####################


loop_
 _symmetry_equiv.id
 _symmetry_equiv.pos_as_xyz
    1 'X,  Y,  Z'
    2 '-X,  Y,  -Z'
    3 'X+1/2,  Y+1/2,  Z+1/2'
    4 '-X+1/2,  Y+1/2,  -Z+1/2'

The only thing I see is different is that your space group is shown as
'I121' whereas mine is just 'I2'

Hope this helps!

Cheers

-- Ian

> -----Original Message-----
> From: owner-ccp...@jiscmail.ac.uk [mailto:owner-ccp...@jiscmail.ac.uk]
On
> Behalf Of Ethan Merritt
> Sent: 08 June 2009 21:56
> To: CCP4BB@jiscmail.ac.uk; Phil Evans
> Subject: mtz2various is broken [ was: Another pointless question ]
> 
> On Friday 08 May 2009 10:36:28 Phil Evans wrote:
> > I2 is always an alternative setting to C2, & Pointless (by default)
> > will choose this (since 1.2.12 I think) if it gives a smaller beta
> > angle than the C2 setting
> >
> > I am assured that this is the IUCr approved "standard", along with
> > always setting primitive orthorhombic space groups with a < b < c
even
> > if this makes eg space group 18 P 2 21 21. However, there are some
> > "old-fashioned" programs :-) which don't like this (arp/warp at
> > present for example, though I believe this will change in future),
so
> > Pointless does offer the option SETTING SYMMETRY-BASED, also an
option
> > in the ccp4i GUI, to choose the "reference" setting and C2
> 
> A follow-up to this discussion.
> 
> I finished refinement, and I am ready to deposit with the PDB.
> However, when I went to produce a *.cif file for deposition, I found
> that mtz2various is confused by the I2 setting.   It kept the cell
> edges and angles from I2, but created a *.cif output file that claims
> the cell is C2 and it lists the symmetry operators for C2.
> 
> I manually corrected the header records in the *.cif file, but the
> program itself should be fixed as well.
> 
> I ran:
> 
> ### CCP4 6.1: MTZ2VARIOUS              version 6.1 : 12/11/08##
> 
> The mtz2various log file contains the line:
> 
>  * Space group = 'I121' (number     5)
> 
> By contrast, running mtzdmp on the input file it is converting reports
> 
>  * Space group = 'I 1 2 1' (number     4005)
> 
> 
>       cheers,
> 
>               Ethan
> 
> 
> > Keeping the obliquity of the cell small has some advantages: it may
> > make map viewing easier, and improve the accuracy of map
interpolation
> > in programs which are a bit casual about doing this properly
> >
> > Phil
> >
> >
> > On 8 May 2009, at 17:45, Ethan Merritt wrote:
> >
> > > I was very surprised recently when a run of pointless chose to
> > > transform my data into spacegroup I2  [*].  Here are excerpts from
the
> > > output log:
> > >
> > > %%%%%%%%%%%%
> > > Selecting space group I 1 2 1 as there is a single space group
with
> > > the highest score
> > > Space group confidence (= Sqrt(Score * (Score - NextBestScore)))
> > > =     0.37
> > > %%%%%%%%%%%%
> > > The input crystal system is C-centred monoclinic
> > > (Cell:   291.8  98.38  148.6        90  120.3     90)
> > > The crystal system chosen for output is body-centred monoclinic
> > > (Cell:   148.6  98.38    252        90  90.33     90)
> > > %%%%%%%%%%%%
> > >
> > > Notice that the log file output doesn't say, for instance,
> > > "you might want to consider the non-standard setting I2".
> > > It says "there is a single space group with the highest score",
> > > and proceeds to convert away from the standard setting C2.
> > >
> > > I am not complaining, as in fact this solved a bit of a mystery
for
> > > me.
> > > The diffraction images had originally been indexed as I222.
> > > Integration
> > > proceeded without a hitch, but the data failed miserably to scale
> > > acceptably.
> > > Running pointless immediately made clear what the problem had
been.
> > >
> > > Instead I am merely curious.
> > > What are the criteria that pointless uses to decide such a thing?
> > > In this case the beta angle is _very_ near to 90.  I have fed
other
> > > C2 data sets to pointless and not seen even a mention of I2 in the
> > > output.  Is the "score" mentioned in the log file some weighted
> > > function that
> > > says the closer beta  approaches 90 after re-indexing, the more
that
> > > re-indexing is preferred?
> > >
> > >   Ethan
> > >
> > >
> > > [*] Not least because I had never previously encountered "I2" as
the
> > >    name of a spacegroup.  Live and learn.
> 
> 
> --
> Ethan A Merritt
> Biomolecular Structure Center
> University of Washington, Seattle 98195-7742



Disclaimer
This communication is confidential and may contain privileged information 
intended solely for the named addressee(s). It may not be used or disclosed 
except for the purpose for which it has been sent. If you are not the intended 
recipient you must not review, use, disclose, copy, distribute or take any 
action in reliance upon it. If you have received this communication in error, 
please notify Astex Therapeutics Ltd by emailing 
i.tic...@astex-therapeutics.com and destroy all copies of the message and any 
attached documents. 
Astex Therapeutics Ltd monitors, controls and protects all its messaging 
traffic in compliance with its corporate email policy. The Company accepts no 
liability or responsibility for any onward transmission or use of emails and 
attachments having left the Astex Therapeutics domain.  Unless expressly 
stated, opinions in this message are those of the individual sender and not of 
Astex Therapeutics Ltd. The recipient should check this email and any 
attachments for the presence of computer viruses. Astex Therapeutics Ltd 
accepts no liability for damage caused by any virus transmitted by this email. 
E-mail is susceptible to data corruption, interception, unauthorized amendment, 
and tampering, Astex Therapeutics Ltd only send and receive e-mails on the 
basis that the Company is not liable for any such alteration or any 
consequences thereof.
Astex Therapeutics Ltd., Registered in England at 436 Cambridge Science Park, 
Cambridge CB4 0QA under number 3751674

Reply via email to