Hi Florian,mthe keyword is TRUSTED_REGION (see http://www.mpimf-heidelberg.mpg.de/~kabsch/xds/html_doc/xds_parameters.html#TRUSTED_REGION= and http://strucbio.biologie.uni-konstanz.de/xdswiki/index.php/XDS.INP in XDSwiki).
HTH, Kay Florian Schmitzberger schrieb:
Dear All,Is there a way to get XDS to include reflections in the far corners of diffraction images.XDS seems to take the high-resolution limit automatically from the edge of the images corresponding to the smallest radius from the center. In my case, with the keyword set to "INCLUDE_RESOLUTION_RANGE=50 0.0" it does not appear to include all reflections (those higher than 1.80 A resolution), although there are reflections to 1.60 A resolution in the corner of the diffraction images. I would like to include these reflections in the integration and processing. (Diffraction data was collected on a ADSC Quantum Q315r detector).Maybe I am missing something obvious. Thank you very much for any comments. Florian
-- Kay Diederichs http://strucbio.biologie.uni-konstanz.de email: [EMAIL PROTECTED] Tel +49 7531 88 4049 Fax 3183 Fachbereich Biologie, Universität Konstanz, Box M647, D-78457 Konstanz
smime.p7s