Where do we submit errors/typos found in the works ? I am keeping track of
the ones I find, but I not sure who to forward them to. 

Thanks,
Max

-----Original Message-----
From: Di Bias, Steve [mailto:[email protected]] 
Sent: Tuesday, September 27, 2011 3:45 PM
To: Max Kamali; [email protected]
Subject: RE: [OSL | CCIE_RS] Vol1 Task 23.4 GTS

You're right on the money Max!

The way I interpreted this is that you need to configure excess as a "0"

>From what I can tell IPexpert didn't configure the Be value and just hit
enter. of course IOS is very polite and will automagically configure it for
us which is why you see those numbers in the DSG

In my opinion anything other than a "0" is a violation of the task

You get the points in my eyes

Thank you,
 
Steve Di Bias
Network Engineer - Information Systems
Valley Health System - Las Vegas
Office - 702- 369-7594
Cell - 702-241-1801
[email protected]

-----Original Message-----
From: [email protected]
[mailto:[email protected]] On Behalf Of Max Kamali
Sent: Tuesday, September 27, 2011 1:08 PM
To: [email protected]
Subject: [OSL | CCIE_RS] Vol1 Task 23.4 GTS

Hi,

Task 23.4 is asking for GTS configs on the frame link se0/0/0.24 of R4, 

Telnet/icmp 15% of BW
ftp 50% BW after shaping
all other traffic gets remaining 35% of BW use WFQ no excess bursts should
be allowed


The DSG is showing the output of a "sh traffic-shape se0/0/0.24" on R4 with
excess burst values. If the requirements ask for no excess burst then
wouldn't the correct answer for this part of the solution be the following

traffic-shape group 101 9600 1200 0
traffic-shape group 102 32000 4000 0
traffic-shape group 103 22400 2800 0

Instead of the dsg configs below?

traffic-shape group 101 9600
traffic-shape group 102 32000
traffic-shape group 103 22400

Thank you,
Max

_______________________________________________
For more information regarding industry leading CCIE Lab training, please
visit www.ipexpert.com

Are you a CCNP or CCIE and looking for a job? Check out
www.PlatinumPlacement.com


UHS Confidentiality Notice:  This e-mail message, including any attachments,
is for the sole use of the intended recipient (s) and may contain
confidential and privileged information.  Any unauthorized review, use,
disclosure or distribution of this information is prohibited.  If this was
sent to you in error, please notify the sender by reply e-mail and destroy
all copies of the original message.

_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit 
www.ipexpert.com

Are you a CCNP or CCIE and looking for a job? Check out 
www.PlatinumPlacement.com

Reply via email to