Add to the LSR; http://lsr.di.unimi.it/LSR/Item?id=1094
Cheers,
Pierre

Le sam. 8 juin 2019 à 15:08, Pierre Perol-Schneider <
pierre.schneider.pa...@gmail.com> a écrit :

> Hi bug squad,
>
> magnifyStaff uses the same key signature padding as a full size staff (0).
> Actually, 100% of the chamber music scores facsimiles found on IMSLP have
> a larger padding on smaller staves.
> So here's a workaround proposal:
>
> \version "2.19.83"
>
> scaleStaff = #(define-music-function (scaleFac) (number?)
>                  #{
>                    \magnifyStaff #scaleFac
>                    \override KeySignature.padding = #(* 2/3 (- 1 scaleFac))
>                  #})
>
> sizeTest = #5/7
> keyTest = { \key cis\major s4*4 \bar "" }
>
> \markup\italic "Default output:"
> <<
>   \new Staff \with { \magnifyStaff #sizeTest } \keyTest
>   \new Staff \keyTest
> >>
>
> \markup\italic "Regular output:"
> <<
>   \new Staff \with { \scaleStaff #sizeTest } \keyTest
>   \new Staff \keyTest
> >>
>
> See also: https://notat.io/viewtopic.php?f=2&t=470
>
> Cheers,
> Pierre
>
_______________________________________________