URL: <https://savannah.gnu.org/bugs/?68828>
Summary: [gropdf] Some unit values are handled incorrectly
Group: GNU roff
Submitter: deri
Submitted: Sat 24 Oct 2026 06:10:02 PM UTC
Category: Driver gropdf
Severity: 3 - Normal
Item Group: Incorrect behaviour
Status: In Progress
Privacy: Public
Assigned to: deri
Open/Closed: Open
Discussion Lock: Unlocked
Planned Release: None
_______________________________________________________
Follow-up Comments:
-------------------------------------------------------
Date: Sat 24 Oct 2026 06:10:02 PM UTC By: Deri James <deri>
Unit 'm' is ems (not millimetres), and a pica (P) is 12pts not 6.