Dear all !

I try to work with a 50 slot Quantum Scalar i3 Library with an IBM LTO7 drive. 
I have a set of 10 LTO7 tapes as a
storage pool in bacula and it has been backing up user directories for a while.

Recently we needed to swap the library chassis due to drive issues. I unmounted 
the library, shut down bacula,
transferred the tapes to the new library (again a Quantum Scalar i3 with the 
drives from the old one), adjusted the scsi
paths of the storage demon config and fired up bacula. During the change I did 
switch from the "st" to the "nst" devices
as apparently these are preferred.

Bacula now sees the changer device, sees the pool of tapes, but when it tried 
to do the next backup it horribly died on
the current append volume with:

22-Mar 08:42 bacula-sd JobId 1245: Error: [SE0203] The Volume=MU0014L7 on 
device="LTO7-0" (/dev/tape/by-id/scsi-
C3EB53C004-nst) appears to be unlabeled.

There is already 45GB of data on that tape and i really dont see why it 
suddenly calls it "unlabeled".

Any idea what could be wrong ?

I did find this thread and am unsure if thats related:
https://bacula-users.narkive.com/JWcvt8eZ/bacula-loses-tape-label

Please help,
Thanks,
Karl

 
-- 