>>>>> On Fri, 1 Mar 2024 11:52:31 +0100, Marco Gaiarin said: > > *unmount storage=CNPVE3Autochanger > Using Catalog "BaculaLNF" > Connecting to Storage daemon CNPVE3Autochanger at cnpve3.cn.lnf.it:9103 ... > 3307 Issuing autochanger "unload Volume AAJ663L9, Slot 4, Drive 0" command. > 3995 Bad autochanger "unload Volume AAJ663L9, Slot 4, Drive 0": ERR=Child > died from signal 15: Termination Results=Program killed by Bacula (timeout) > 3002 Device ""LTO9Storage0" (/dev/nst0)" unmounted. > > So, this seems solved only by: > > 1) increasing bacula timeout when run autochanger script; i've look into the > docs but i've not found the knob; i've not looked at code, but i suppose is > hardcoded somewhere...
Isn't it Maximum Changer Wait? See https://www.bacula.org/13.0.x-manuals/en/main/Storage_Daemon_Configuratio.html#SECTION0024300000000000000000 __Martin _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users