Hi Radosław , yes my linux is able to recognize . Please see below
mtx -f /dev/changer status Storage Changer /dev/changer:2 Drives, 49 Slots ( 0 Import/Export ) Data Transfer Element 0:Empty Data Transfer Element 1:Full (Storage Element 25 Loaded):VolumeTag = NY0175M8 Storage Element 1:Full :VolumeTag=NY0155M8 Storage Element 2:Full :VolumeTag=NY0156M8 Storage Element 3:Empty:VolumeTag= lsscsi -g | grep mediumx [1:0:3:1] mediumx QUANTUM Scalar i3-i6 260G /dev/sch0 /dev/sg8 lrwxrwxrwx 1 root root 3 Mar 27 00:00 changer-sg8 -> sg8 lrwxrwxrwx 1 root root 3 Mar 27 00:00 changer -> sg8 Best Regards Vikrant ________________________________ From: Radosław Korzeniewski <rados...@korzeniewski.net> Sent: Tuesday, March 30, 2021 12:53 PM To: Vikrant Agarwal <vikran...@hotmail.com> Cc: bacula-users@lists.sourceforge.net <bacula-users@lists.sourceforge.net> Subject: Re: [Bacula-users] After upgrading Library firmware drives not working Hello, wt., 30 mar 2021 o 05:40 Vikrant Agarwal <vikran...@hotmail.com<mailto:vikran...@hotmail.com>> napisał(a): Hi All , After upgrading firmware on the quantum to the newest , the Drives doesn’t seems to be getting reconzied on the bacula . Getting below error , Any advice and help please ? Enter autochanger drive[0]: Enter autochanger slot: 48 3307 Issuing autochanger "unload slot 49, drive 0" command. 3995 Bad autochanger "unload slot 49, drive 0": ERR=Child exited with code 1 Results=Unloading drive 0 into Storage Element 49...mtx: Request Sense: Long Report=yes mtx: Request Sense: Valid Residual=no mtx: Request Sense: Error Code=70 (Current) mtx: Request Sense: Sense Key=Illegal Request mtx: Request Sense: FileMark=no mtx: Request Sense: EOM=no mtx: Request Sense: ILI=no mtx: Request Sense: Additional Sense Code = 53 mtx: Request Sense: Additional Sense Qualifier = 01 mtx: Request Sense: Field in Error = 00 mtx: Request Sense: BPV=no mtx: Request Sense: Error in CDB=no mtx: Request Sense: SKSV=yes mtx: Request Sense: Field Pointer = 00 00 MOVE MEDIUM from Element Address 256 to 4144 Failed 3901 Unable to open device ""Drive-0" (/dev/sg2)": ERR=dev.c:513 Unable to open device "Drive-0" (/dev/sg2): ERR=Operation not permitted Are you absolutely sure that your autochanger/robot is at /dev/sg2 now? You can always check if your system recognizes your tape library using commands: lsscsi and mtx. If all in with these commands will work fine then Bacula will work too. best regards -- Radosław Korzeniewski rados...@korzeniewski.net<mailto:rados...@korzeniewski.net>
_______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users