Hello,

I'm a new user who has just set up bacula on a couple of
machines. During my initial tests, things were working fine, but
when I went into production I started seeing these errors. These
errors only appear to happen when a backup is big enough to cross
volume size boundaries. (I keep my volumes at 4GB in size and I do
disk backups only with Full/Differential/Incremental pools).

I poked the list a little with the search engine about this error
but was unsuccessful at finding something similar.

23-Dec 18:46 SD-0:xxx.yyy.zzz JobId 4: End of medium on Volume
"FullBackup-0005" Bytes=3,999,937,436 Blocks=62,003 at 23-Dec-2015 18:46.
23-Dec 18:46 DIR:xxx.yyy.zzz JobId 4: Created new Volume="FullBackup-0006",
Pool="FullBackup", MediaType="Disk-0" in catalog.
23-Dec 18:46 SD-0:xxx.yyy.zzz JobId 4: Labeled new Volume "FullBackup-0006" on
file device "Device-Disk-0" (/backups/bacula-archive/disk-0).
23-Dec 18:46 SD-0:xxx.yyy.zzz JobId 4: Wrote label to prelabeled Volume
"FullBackup-0006" on file device "Device-Disk-0" 
(/backups/bacula-archive/disk-0)
23-Dec 18:46 SD-0:xxx.yyy.zzz JobId 4: New volume "FullBackup-0006" mounted on
device "Device-Disk-0" (/backups/bacula-archive/disk-0) at 23-Dec-2015 18:46.
23-Dec 18:47 DIR:xxx.yyy.zzz JobId 4: Error: Catalog error updating file
digest. bdb.h:101 Update failed: affected_rows=0 for UPDATE File SET
MD5='oGhRwHZ+y+mWb+fv9ppFrA' WHERE FileId=6148914691236517205
23-Dec 18:50 SD-0:xxx.yyy.zzz JobId 4: End of medium on Volume
"FullBackup-0006" Bytes=3,999,937,664 Blocks=62,003 at 23-Dec-2015 18:50.
23-Dec 18:50 DIR:xxx.yyy.zzz JobId 4: Created new Volume="FullBackup-0007",
Pool="FullBackup", MediaType="Disk-0" in catalog.
23-Dec 18:50 SD-0:xxx.yyy.zzz JobId 4: Labeled new Volume "FullBackup-0007" on
file device "Device-Disk-0" (/backups/bacula-archive/disk-0).
23-Dec 18:50 SD-0:xxx.yyy.zzz JobId 4: Wrote label to prelabeled Volume
"FullBackup-0007" on file device "Device-Disk-0" 
(/backups/bacula-archive/disk-0)
23-Dec 18:50 SD-0:xxx.yyy.zzz JobId 4: New volume "FullBackup-0007" mounted on
device "Device-Disk-0" (/backups/bacula-archive/disk-0) at 23-Dec-2015 18:50.
23-Dec 18:50 DIR:xxx.yyy.zzz JobId 4: Error: Catalog error updating file
digest. bdb.h:101 Update failed: affected_rows=0 for UPDATE File SET
MD5='Hh8yl5gZPABvG9+8Ow50gQ' WHERE FileId=6148914691236517205

The above produced an "OK -- with warnings" result of the backup and I was able
to restore things out of it.

Something which might be relevant is that when I read this portion
of the manual:

"However, one additional point is that in the case that no match
was found, Bacula will use the options found in the last Options
resource. As a consequence, if you want a particular set of ``default''
options, you should put them in an Options resource after any other
Options. "

I fixed all of my file sets to have a last Options block in which I put the
signature=MD5 and compression=GZIP1 specification because otherwise there
were cases where compression didn't happen and such if they were first.

Does anyone know what this is or how I can fix it?

Thank you!

-pete


------------------------------------------------------------------------------
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to