On 01/21/2015 06:41 PM, Bill Arlofski wrote: > Bacula has a hard-coded 6 day limit on a job's run time. 518401 seconds = > 6.00001157 days, so it appears that is the cause for the watchdog killing the > job.
Hard-coded, huh? Nobody's tried backing up that big data I keep hearing about? > Does it ask you for a new volume? No. Good guess, but the storage is a vchanger and it's working just fine. I killed the lot and replaced the spool disk in the unlikely case that was slowing things down -- unlikely because it's a tler disk and shouldn't have this particular failure mode. I restarted the offending job, we'll see what happens... -- Dimitri Maziuk Programmer/sysadmin BioMagResBank, UW-Madison -- http://www.bmrb.wisc.edu
signature.asc
Description: OpenPGP digital signature
------------------------------------------------------------------------------ New Year. New Location. New Benefits. New Data Center in Ashburn, VA. GigeNET is offering a free month of service with a new server in Ashburn. Choose from 2 high performing configs, both with 100TB of bandwidth. Higher redundancy.Lower latency.Increased capacity.Completely compliant. http://p.sf.net/sfu/gigenet