Hi there, I'd like to recycle our 4 weekly (differential) backup tapes automatic, but it does not work. I'd appreciate any help.
After studying the documentation and the error reports, I have no clue what's the problem. My relevant Config: bacula-dir 5.2.6: Pool { AutoPrune = yes Recycle Current Volume = yes Maximum Volumes = 1 Volume Use Duration = 5 days Volume Retention = 25 days ... } As far as I know the directive "Volume Use Duration" in the pool should overwrite any given longer periods in other directives. I receive this error info: "Cannot automatically recycle current volume, as it still contains unpruned data or the Volume Retention time has not expired" I don't get this, with the directives "AutoPrune" and "Volume Retention" this should not happen... Any ideas? Thanks a lot, Helge ------------------------------------------------------------------------------ Open source business process management suite built on Java and Eclipse Turn processes into business applications with Bonita BPM Community Edition Quickly connect people, data, and systems into organized workflows Winner of BOSSIE, CODIE, OW2 and Gartner awards http://p.sf.net/sfu/Bonitasoft _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users