I'm on bacula 3.0.1, btw.

Thanks. It's confusing, b/c with these same settings it's no auto-recycling
again.
I don't see how 'MaxVols' would effect things, b/c I don't think things are
setup to automatically add new volumes.
And 'Recycle Oldest Volume' seems to only consider job and file retention
times, which in my case are much greater than my volume retention period. I
could change those of course. But I'm trying to leave things as they were
setup when I inherited this system.

-M


On Thu, Aug 1, 2013 at 9:56 AM, Uwe Schuerkamp <uwe.schuerk...@nionex.net>wrote:

> On Wed, Jul 31, 2013 at 03:34:50PM -0400, Michael Stauffer wrote:
> >
> > PoolId: 6
> > Name: Differential
> >          NumVols: 6
> >          MaxVols: 0
>
> Wouldn't you want to set the "maxvols" parameter in your pool
> definition too together with "recycle oldest volume" to force bacula
> to recycle the oldest volume?
>
> Cheers, Uwe
>
> --
> NIONEX --- Ein Unternehmen der Bertelsmann SE & Co. KGaA
>
>
>
------------------------------------------------------------------------------