In the webacula interface, the state of the current task is set to : "is waiting on Storage Tape"
Come on, the tape is labeled, mounted ! What's wrong ! gnowar wrote: > > I think I've spoken too early.. > > I don't have a mistake now, but nothing happens.. > > lan-backup01-dir shell command: run BeforeJob > "/opt/bacula/sysconf/mount_tape" > BeforeJob: Connecting to Director lan-backup01:9101 > BeforeJob: 1000 OK: lan-backup01-dir Version: 5.0.1 (24 February 2010) > BeforeJob: Enter a period to cancel a command. > BeforeJob: mount storage=Tape > BeforeJob: Automatically selected Catalog: MyCatalog > BeforeJob: Using Catalog "MyCatalog" > BeforeJob: 3001 OK mount requested. Device="LTO-2" (/dev/st0) > BeforeJob: You have messages. > Start Backup JobId 146, Job=BackupCvsOnTape.2010-05-27_10.24.19_41 > > I remember the old times when recycling was working, I saw in the log the > prune, recycle, relabel etc. > > There is nothing here, the process is frozen.. > > Any idea ? > > > John M. Drescher wrote: >> >> On Wed, May 26, 2010 at 10:20 AM, John Drescher <dresche...@gmail.com> >> wrote: >>> On Wed, May 26, 2010 at 9:57 AM, John Drescher <dresche...@gmail.com> >>> wrote: >>>>> I've a problem (I guess) cause bacula doesn't recycle my tape, even >>>>> when >>>>> volume retention is over. >>>>> >>>>> Here is the pool part of my bacula-dir.conf : >>>>> >>>>> # Tape Pool definition >>>>> Pool { >>>>> Name = TapePool >>>>> Pool Type = Backup >>>>> Recycle = yes # Bacula can automatically >>>>> recycle >>>>> Volumes >>>>> AutoPrune = yes # Prune expired volumes >>>>> Volume Use Duration = 18 hours >>>>> Volume Retention = 20 days # one year >>>>> Maximum Volumes = 1 # Limit number of Volumes in Pool >>>>> Maximum Volume Jobs = 2 >>>>> Label Format = "Day-" >>>>> } >>>>> >>>>> Look at the tape day-20A (retention period and the last written thing) >>>>> http://www.flickr.com/photos/47940...@n08/4641302169/sizes/l/ >>>>> >>>>> And now look at the error (1month after the last written thing on the >>>>> tape, >>>>> bacula seems to not recycle the tape..) >>>>> http://www.flickr.com/photos/47940...@n08/4641307241/sizes/l/ >>>>> >>>>> >>>>> There is a problem, right ? >>>>> -- >>>> >>>> Yes there is a problem with your configuration. You have it configured >>>> to use only 1 volume. Write up to 2 jobs on that 1 volume then wait 20 >>>> days until it can be used again. I do not think this is what you want. >>>> >>> I missed the other condition. On top of a maximum of 2 jobs to a >>> volume you limit the volume to 18 hours of usage. So the second job >>> must be started within 18 hours of the first. >>> >> >> Sorry. I see what you mean from the pictures. I would still get rid of >> Maximum Volumes = 1 because that may be confusing bacula since you >> have way more than 1 volume in the pool. >> >> John >> >> ------------------------------------------------------------------------------ >> >> _______________________________________________ >> Bacula-users mailing list >> Bacula-users@lists.sourceforge.net >> https://lists.sourceforge.net/lists/listinfo/bacula-users >> >> > > -- View this message in context: http://old.nabble.com/Recycling-is-not-working.-tp28680351p28692000.html Sent from the Bacula - Users mailing list archive at Nabble.com. ------------------------------------------------------------------------------ _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users