Hi ! I had a try this morning with the btape fill again, after erasing my tapes and relabeling them. The test was successfull. Starting a few jobs at the moment to see if things improve... A strange thing I noticed ... which is the correct storage device parameter "RandomAccess" or "Random Access" (= no, for tapes) ... maybe it's that ? Le 06.05.2009 19:18, Hayden Katzenellenbogen a écrit : Yvan, I see that you are running a TL2000 have you run the btape fill test on your system. If you have did you get any errors?I seem to be getting the following one. 05-May 15:17 btape: Fatal Error at dev.c:1705 because: dev.c:1704 Attempt to WEOF on non-appendable Volume Thanks H -----Original Message----- From: yvan [mailto:y...@skywalker.is-a-chef.com] Sent: Monday, May 04, 2009 4:14 AM To: bacula-users@lists.sourceforge.net Subject: Re: [Bacula-users] Tape MTEOM error with Dell TL2000 (IBM TS3100) Hi, thank you for the advices. We have very similar configurations, and I'm sure I'm not too far from the solution. I tried to use your settings in the storage daemon config file, and the "mt" options as well, than I didn't try so far. But, as soon as I put those settings, I have another error Hardware End of Medium = No # defaut is Yes Fast Forward Space File = No # This line required if above which is : 3-May 02:20 setmseblx0007-sd JobId 170: Error: Unable to position to end of data on device "IBMLTO4" (/dev/nst0): ERR=dev.c:1354 ioctl MTFSF error on "IBMLTO4" (/dev/nst0). ERR=Input/output error. Strange that it works for you then ... I issued all the "mt" commands you wrote. Tapeinfo gives me the samed infos as you have, but it's MTFSF error or MTEOM ... Regards Yvan BroccardI also had very similar problems when I first started testing Bacula.Now,I have both TS3100 & TS3200 models running without any issues on RedHat 4 and 5 servers. My configurations are: Autochanger { Name = TS3200_1_DRV1 Device = LTO4_1 Changer Device = /dev/sg7 # This is mapped to theAutoLoaderChanger Command = "/etc/bacula/config/mtx-changer %c %o %S %a%d"} Device { Name = LTO4_1 Drive Index = 0 Media Type = LTO4 Archive Device = /dev/nst0 # Device nstX created automatically by st daemon. AutoChanger = yes AutomaticMount = yes; # when device opened, read it AlwaysOpen = yes; # Default value yes RemovableMedia = yes; RandomAccess = no; Requires Mount = no; Maximum Open Wait = 300 # Default value Maximum Rewind Wait = 300 # Default value Maximum Changer Wait = 120 # default is 120 secs Maximum Job Spool Size = 2G # default is unlimited Spool Directory = "/export/shared/spool" Label Type = IBM Check Labels = yes LabelMedia = no; Hardware End of Medium = No # defaut is Yes Fast Forward Space File = No # This line required if above HEOM is set to "No" BSF at EOM = no # Default is no Two EOF = no Volume Poll Interval = 300 # Poll the drive to seek thestatus} I also changed the LTO4 tape drives' parameters with the "mt" command. 1. mt -f /dev/st0 stsetoptions 2. mt -f /dev/st0 compression 3. mt -f /dev/st0 stsetoptions buffer-writes 4. mt -f /dev/st0 stsetoptions async-write 5. mt -f /dev/st0 stsetoptions fast-eod 6. mt -f /dev/st0 stsetoptions two-fms 7. tapeinfo -f /dev/sg2 Product Type: Tape Drive Vendor ID: 'IBM ' Product ID: 'ULT3580-TD4 ' Revision: '77B1' Attached Changer: No SerialNumber: '1310016341' MinBlock:1 MaxBlock:16777215 SCSI ID: 2 SCSI LUN: 0 Ready: yes BufferedMode: yes Medium Type: 0x48 Density Code: 0x46 BlockSize: 0 DataCompEnabled: yes DataCompCapable: yes DataDeCompEnabled: yes CompType: 0x1 DeCompType: 0x1 Block Position: 7920778 HTH Cheers, Win------------------------------------------------------------------------ ------ Register Now & Save for Velocity, the Web Performance & Operations Conference from O'Reilly Media. Velocity features a full day of expert-led, hands-on workshops and two days of sessions from industry leaders in dedicated Performance & Operations tracks. Use code vel09scf and Save an extra 15% before 5/3. http://p.sf.net/sfu/velocityconf _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users |
------------------------------------------------------------------------------ The NEW KODAK i700 Series Scanners deliver under ANY circumstances! Your production scanning environment may not be a perfect world - but thanks to Kodak, there's a perfect scanner to get the job done! With the NEW KODAK i700 Series Scanner you'll get full speed at 300 dpi even with all image processing features enabled. http://p.sf.net/sfu/kodak-com
_______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users