Hi, I have a 3 drive autochanger (bacula 2.2.8). Right now I configure each job to use one of the 3 drives, not the changer device.
Storage { Name = Neo4100 Address = .... SDPort = 9103 Password = "wiped" Device = Neo4100 Media Type = LTO4 Autochanger = yes Heartbeat Interval = 5min Maximum Concurrent Jobs = 3 } Storage { Name = Neo4100-LTO4-D1 Address = .... SDPort = 9103 Password = "wiped" Device = ULTRIUM-TD4-D1 Media Type = LTO4 Maximum Concurrent Jobs = 1 [2 more drives] And in the client's job config I then use Storage = Neo4100-LTO4-D1 or Storage = Neo4100-LTO4-D2 Now I would like to go back to the more typical bacula approach, where I use the changer device in the client's job config. But I don't want concurrent jobs running on each drive. I want that it's possible to run 3 jobs on the changer (one for each drive), but only one on each drive at the same time. I could achieve that with different Priorities, but then these jobs are blocking jobs which are using other storage devices. Any ideas? Ralf ------------------------------------------------------------------------------ SF.Net email is Sponsored by MIX09, March 18-20, 2009 in Las Vegas, Nevada. The future of the web can't happen without you. Join us at MIX09 to help pave the way to the Next Web now. Learn more and register at http://ad.doubleclick.net/clk;208669438;13503038;i?http://2009.visitmix.com/ _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users