New Bacula user here- I've gone over the config documentation a number 
of times and I hope I'm missing something small...but I'm having issues 
with 2-Sun L25s linked together with a Quantum StackLink on Debian etch 
(2.6.x) with MySQL 5.0.30.

I've had the same issues with both the prepackaged Debian packages and 
building from source, which suggests a config file problem...

I can load/unload tapes just fine and do all mtx commands with no 
problems.  All bacula services start fine (running as root).  All 
devices exist under /dev and permissions are correct for root.  Each L25 
has 2 drives available, giving me 4 drives able to write 
simultaneously.  However, bconsole won't run 'update slots scan' for the 
autochanger (since it tries to access the drive's archive device instead 
of the changer device), and I can successfully run 'btape test' and 
'btape fill', but autochanger does NOTHING- just gives me another * prompt.

----------------------------------------------------------------
results from dmesg:
ch 2:0:0:0: Attached scsi changer ch0
ch 2:0:0:0: Attached scsi generic sg0 type 8
st 2:0:1:0: Attached scsi tape st0
st 2:0:1:0: Attached scsi generic sg1 type 1
st 2:0:2:0: Attached scsi tape st1
st 2:0:2:0: Attached scsi generic sg2 type 1
st 2:0:3:0: Attached scsi tape st2
st 2:0:3:0: Attached scsi generic sg3 type 1
st 2:0:4:0: Attached scsi tape st3
st 2:0:4:0: Attached scsi generic sg4 type 1
----------------------------------------------------------------
from bacula-dir:
Storage {
  Name = StackLink
  Address = myhost
  SDPort = 9103
  Password = ""
  Device = StackLink
  Autochanger = yes
  Media Type = LTO-2
}
-----------------------------------------------------------------
from bacula-sd:
Autochanger {
  Name = StackLink
  Device = L25-1-1, L25-1-2, L25-2-1, L25-2-2
  Changer Device = /dev/sg0
  Changer Command = "/etc/bacula/mtx-changer %c %o %d %S" # I've 
modified mtx-changer to use drive before slot
}

Device {
  Name = L25-1-1
  Media Type = LTO-2
  Archive Device = /dev/nst0
  AutomaticMount = yes;
  Device Type = Tape
  AlwaysOpen = yes;
  RemovableMedia = yes;
  RandomAccess = no;
  Autoselect = yes
  Drive Index = 0;
}

Device {
  Name = L25-1-2
  Media Type = LTO-2
  Archive Device = /dev/nst1
  AutomaticMount = yes;
  Device Type = Tape
  AlwaysOpen = yes;
  RemovableMedia = yes;
  RandomAccess = no;
  Autoselect = yes
  Drive Index = 1;
}

Device {
  Name = L25-2-1
  Media Type = LTO-2
  Archive Device = /dev/nst2
  AutomaticMount = yes;
  Device Type = Tape
  AlwaysOpen = yes;
  RemovableMedia = yes;
  RandomAccess = no;
  Autoselect = yes
  Drive Index = 2;
}

Device {
  Name = L25-2-2
  Media Type = LTO-2
  Archive Device = /dev/nst3
  AutomaticMount = yes;
  Device Type = Tape
  AlwaysOpen = yes;
  RemovableMedia = yes;
  RandomAccess = no;
  Autoselect = yes
  Drive Index = 3;
}
----------------------------------------------------
result from bconsole 'update slots scan':
*update slots scan
Automatically selected Catalog: MyCatalog
Using Catalog "MyCatalog"
Automatically selected Storage: StackLink
Connecting to Storage daemon StackLink at myhost:9103 ...
3993 Device "L25-1-1" (/dev/nst0) not an autochanger device.
Device "StackLink" has 0 slots.
No slots in changer to scan.
----------------------------------------------------

Thanks in advance for any help you can offer.
-Justin

-------------------------------------------------------------------------
Take Surveys. Earn Cash. Influence the Future of IT
Join SourceForge.net's Techsay panel and you'll get the chance to share your
opinions on IT & business topics through brief surveys - and earn cash
http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to