New Bacula user here- I've gone over the config documentation a number of times and I hope I'm missing something small...but I'm having issues with 2-Sun L25s linked together with a Quantum StackLink on Debian etch (2.6.x) with MySQL 5.0.30.
I've had the same issues with both the prepackaged Debian packages and building from source, which suggests a config file problem... I can load/unload tapes just fine and do all mtx commands with no problems. All bacula services start fine (running as root). All devices exist under /dev and permissions are correct for root. Each L25 has 2 drives available, giving me 4 drives able to write simultaneously. However, bconsole won't run 'update slots scan' for the autochanger (since it tries to access the drive's archive device instead of the changer device), and I can successfully run 'btape test' and 'btape fill', but autochanger does NOTHING- just gives me another * prompt. ---------------------------------------------------------------- results from dmesg: ch 2:0:0:0: Attached scsi changer ch0 ch 2:0:0:0: Attached scsi generic sg0 type 8 st 2:0:1:0: Attached scsi tape st0 st 2:0:1:0: Attached scsi generic sg1 type 1 st 2:0:2:0: Attached scsi tape st1 st 2:0:2:0: Attached scsi generic sg2 type 1 st 2:0:3:0: Attached scsi tape st2 st 2:0:3:0: Attached scsi generic sg3 type 1 st 2:0:4:0: Attached scsi tape st3 st 2:0:4:0: Attached scsi generic sg4 type 1 ---------------------------------------------------------------- from bacula-dir: Storage { Name = StackLink Address = myhost SDPort = 9103 Password = "" Device = StackLink Autochanger = yes Media Type = LTO-2 } ----------------------------------------------------------------- from bacula-sd: Autochanger { Name = StackLink Device = L25-1-1, L25-1-2, L25-2-1, L25-2-2 Changer Device = /dev/sg0 Changer Command = "/etc/bacula/mtx-changer %c %o %d %S" # I've modified mtx-changer to use drive before slot } Device { Name = L25-1-1 Media Type = LTO-2 Archive Device = /dev/nst0 AutomaticMount = yes; Device Type = Tape AlwaysOpen = yes; RemovableMedia = yes; RandomAccess = no; Autoselect = yes Drive Index = 0; } Device { Name = L25-1-2 Media Type = LTO-2 Archive Device = /dev/nst1 AutomaticMount = yes; Device Type = Tape AlwaysOpen = yes; RemovableMedia = yes; RandomAccess = no; Autoselect = yes Drive Index = 1; } Device { Name = L25-2-1 Media Type = LTO-2 Archive Device = /dev/nst2 AutomaticMount = yes; Device Type = Tape AlwaysOpen = yes; RemovableMedia = yes; RandomAccess = no; Autoselect = yes Drive Index = 2; } Device { Name = L25-2-2 Media Type = LTO-2 Archive Device = /dev/nst3 AutomaticMount = yes; Device Type = Tape AlwaysOpen = yes; RemovableMedia = yes; RandomAccess = no; Autoselect = yes Drive Index = 3; } ---------------------------------------------------- result from bconsole 'update slots scan': *update slots scan Automatically selected Catalog: MyCatalog Using Catalog "MyCatalog" Automatically selected Storage: StackLink Connecting to Storage daemon StackLink at myhost:9103 ... 3993 Device "L25-1-1" (/dev/nst0) not an autochanger device. Device "StackLink" has 0 slots. No slots in changer to scan. ---------------------------------------------------- Thanks in advance for any help you can offer. -Justin ------------------------------------------------------------------------- Take Surveys. Earn Cash. Influence the Future of IT Join SourceForge.net's Techsay panel and you'll get the chance to share your opinions on IT & business topics through brief surveys - and earn cash http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users