I am running Bacula 1.38.11 under CentOS 4.4 with a Quantum SuperLoader3
LTO-3 changer.  I have only one magazine for it so it can hold 8 tapes.  I
keep a cleaning tape in slot 8 and rotate backup tapes in slots 1-7.

My problem is that sometimes bacula goes into this loop and I just don't
know what to do:

16-Nov 09:28 nts-sd: 3301 Issuing autochanger "loaded drive 0" command.
16-Nov 09:28 nts-sd: 3302 Autochanger "loaded drive 0", result is Slot 3.
16-Nov 09:28 nts-sd: 3301 Issuing autochanger "loaded drive 0" command.
16-Nov 09:28 nts-sd: 3302 Autochanger "loaded drive 0", result is Slot 3.
16-Nov 09:28 nts-sd: 3301 Issuing autochanger "loaded drive 0" command.
16-Nov 09:28 nts-sd: 3302 Autochanger "loaded drive 0", result is Slot 3.
16-Nov 09:28 nts-sd: 3301 Issuing autochanger "loaded drive 0" command.
16-Nov 09:28 nts-sd: 3302 Autochanger "loaded drive 0", result is Slot 3.
16-Nov 09:28 nts-sd: 3301 Issuing autochanger "loaded drive 0" command.
16-Nov 09:28 nts-sd: 3302 Autochanger "loaded drive 0", result is Slot 3.
16-Nov 09:28 nts-sd: 3301 Issuing autochanger "loaded drive 0" command.
16-Nov 09:29 nts-sd: 3302 Autochanger "loaded drive 0", result is Slot 3.

Why does it keep doing that, over and over again?

16-Nov 09:29 nts-sd: Please mount Volume "MCL376L3" on Storage Device
"Drive-1" (/dev/nst0) for Job nsecure.2006-11-16_09.28.42
*mount
The defined Storage resources are:
     1: File
          2: Autochanger
          Select Storage resource (1-2): 2
Connecting to Storage daemon Autochanger at 10.10.0.8:9103 ...
3001 OK mount. Device="Drive-1" (/dev/nst0)
*
16-Nov 09:29 nts-sd: 3301 Issuing autochanger "loaded drive 0" command.
16-Nov 09:29 nts-sd: 3302 Autochanger "loaded drive 0", result is Slot 3.
16-Nov 09:29 nts-sd: Please mount Volume "MCL376L3" on Storage Device
"Drive-1" (/dev/nst0) for Job nsecure.2006-11-16_09.28.42
*umount
The defined Storage resources are:
     1: File
          2: Autochanger
          Select Storage resource (1-2): 2
3301 Issuing autochanger "loaded drive 0" command.
3302 Autochanger "loaded drive 0", result is Slot 3.
3307 Issuing autochanger "unload slot 3, drive 0" command.
3001 Device "Drive-1" (/dev/nst0) unmounted.
*mount
The defined Storage resources are:
    1: File
    2: Autochanger
    Select Storage resource (1-2): 2
3301 Issuing autochanger "loaded drive 0" command.
3302 Autochanger "loaded drive 0", result: nothing loaded.
3301 Issuing autochanger "loaded drive 0" command.
3302 Autochanger "loaded drive 0", result: nothing loaded.
3905 Device "Drive-1" (/dev/nst0) open but no Bacula volume is mounted.
If this is not a blank tape, try unmounting and remounting the Volume.


What the hell does it want from me?  I have tried umounting and
remounting, it just goes back into this crazy loop.  I tried deleting all
the volumes, erasing all the tapes, doing "label barcode"... it is driving
me NUTS.

I have 2 sets of 7 LTO-3 tapes.  I would like to be able to go over to the
colocation site where the drive is once a week, remove the used tapes and
put in fresh ones, and have bacula continue to back up every night.  But
everytime I have to change the tapes it literally takes me DAYS of
screwing with it before it stabilizes again.

-- 
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.


-------------------------------------------------------------------------
Take Surveys. Earn Cash. Influence the Future of IT
Join SourceForge.net's Techsay panel and you'll get the chance to share your
opinions on IT & business topics through brief surveys - and earn cash
http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV
_______________________________________________
Bacula-users mailing list
Bacula-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to