I am still in the testing phase and I get what seems to me to be a strange problem. The scenario is as follows:
1. Bacula daemons are started normally. 2. bconsole is started. 3. *run Client1 is issued. 4. Bacula sends "Intervention needed" message asking to mount Volume "Bacula02" on Storage Device "DDS-4" 5. Tape is ejected manually and true it was a wrong tape (not a bacula volume). 6. Volume "Bacula02" is inserted. 7. *mount storage=DDS-4 is not accepted and produce the following set of messages: *mount DDS-4 block.c:782 Read error at file:blk 0:0 on device /dev/nst0. ERR=Input/output error. block.c:782 Read error at file:blk 0:0 on device /dev/nst0. ERR=Input/output error. 3902 Cannot mount Volume on Storage Device "/dev/nst0" because: Requested Volume "" on /dev/nst0 is not a Bacula labeled Volume, because: ERR=block.c:782 Read error at file:blk 0:0 on device /dev/nst0. ERR=Input/output error. 3905 Device /dev/nst0 open but no Bacula volume is mounted. If this is not a blank tape, try unmounting and remounting the Volume. Unmounting and remounting the volume does not change anything. Trying with another Bacula labeled volume follows the same scenario. Stopping and starting bacula doesn't change anything either. First of all I like to understand what bacula is trying to tell me with these messages. Secondly can a wrong tape (not a bacula volume) cause this sort of errors and are the volumes which bacula would not accept now unusable for bacula forever? -- Regards, Erik P. Olsen ------------------------------------------------------- SF.Net email is sponsored by: Tame your development challenges with Apache's Geronimo App Server. Download it for free - -and be entered to win a 42" plasma tv or your very own Sony(tm)PSP. Click here to play: http://sourceforge.net/geronimo.php _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users