On 13 Sep 2005 at 19:23, Arunav Mandal wrote: > ----- Original Message ----- > From: "Dan Langille" <[EMAIL PROTECTED]> > To: "Arunav Mandal" <[EMAIL PROTECTED]> > Cc: <bacula-users@lists.sourceforge.net> > Sent: Tuesday, September 13, 2005 7:07 PM > Subject: Re: [Bacula-users] Tape error > > > > On 13 Sep 2005 at 19:00, Arunav Mandal wrote: > > > >> I have seen errors given below quite often even with new tapes. This > >> happens mostly when I try to restore files from a tape that has been > >> recently written and got a Append tag. It restores fine but when it > >> try to write again this error comes up maybe because the tape media > >> has moved forward or backwards. I use 1.36.3. > >> > >> Error: I canot write on Volume "SDLT010" because: > >> The number of files mismatch! Volume=303 Catalog=301 > >> 13-Sep 16:32 abc-sd: Marking Volume "SDLT010" in Error in Catalog. > > > > I understand this is a known bug, fixed in CVS. > > What happens when I change the error to Append manually will the tape > be used again?
Yes. -- Dan Langille : http://www.langille.org/ BSDCan - The Technical BSD Conference - http://www.bsdcan.org/ ------------------------------------------------------- SF.Net email is Sponsored by the Better Software Conference & EXPO September 19-22, 2005 * San Francisco, CA * Development Lifecycle Practices Agile & Plan-Driven Development * Managing Projects & Teams * Testing & QA Security * Process Improvement & Measurement * http://www.sqe.com/bsce5sf _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users