Arunav Mandal wrote:
> ----- Original Message ----- From: "Dan Langille" <[EMAIL PROTECTED]>
>> On 13 Sep 2005 at 19:00, Arunav Mandal wrote:
>>> Error: I canot write on Volume "SDLT010" because:
>>> The number of files mismatch! Volume=303 Catalog=301
>>> 13-Sep 16:32 abc-sd: Marking Volume "SDLT010" in Error in Catalog.
>>
>> I understand this is a known bug, fixed in CVS.
> 
> What happens when I change the error to Append manually will the tape be
> used again?

You should also change the Catalog Volume record to make the File count
in the Catalog match the number Bacula is reading from the Volume.  In
your example above, you would change VolStatus to "Append" and VolFiles
to 303.


-- 
 Phil Stracchino       [EMAIL PROTECTED]
    Renaissance Man, Unix generalist, Perl hacker
 Mobile: 603-216-7037         Landline: 603-886-3518


-------------------------------------------------------