On Sun, 2005-08-21 at 01:38 -0400, Phil Stracchino wrote:
> Thomas Simmons wrote:
> > No one has any thoughts on this?
> > 
> > Thanks,
> > Thomas
> > 
> > Thomas Simmons wrote:
> > 
> >> Hello Everyone,
> >>  From what I understand, if I have "Full Backup Pool = Full-Pool" in
> >> the job resource then any job on that client that gets upgraded to
> >> full, should use the "Full-Pool". This is not happening and is really
> >> a big problem for laptops that are not on site everynight. If the
> >> laptop misses the normal full backup, the job will go to a tape in the
> >> "Inc-Pool", which has a much shorter retention period than the
> >> "Full-Pool". Here's a few snippets from my config files and some
> >> bacula output. Thanks for any help with this.
> 
> 
> There is, to my recollection, a long-standing bug in this regard that
> when a job is automatically promoted to a higher level, any specific
> Pool for that level is not applied.
> 
> I don't know what the status is on fixing this behavior.
I can't guarantee that the bug is fixed but I was just running the
latest cvs version and there it did use the proper pool when I just
kicked of a Inc on a brand new system.
> 




-------------------------------------------------------