On Wednesday 10 August 2005 22:20, Chris Linn wrote: > greetings, > > i am trying to get 1.37.25 working with a Compaq StorageWorks > SSL2020 dual AIT2 drive tape library. i have gone over the > devel manual autochanger section and tweeked the director and > storage configs as explained there. when i try running > "btape test" it works fine filling the tape but issues this > at the very end after all the output from testing: > > Autochanger enabled, but no name or no command device specified. > > current copies of my configs are at: > http://www.cec.mtu.edu/~celinn/bacula/ > > i must be missing something..
In the version you are using, there is a bug that does not recognize the command device in the Autochanger resource. Either add them back to your Device resources, or update to a later version of Bacula. I *think* it is fixed in 1.37.30. > > chris > > > ------------------------------------------------------- > SF.Net email is Sponsored by the Better Software Conference & EXPO > September 19-22, 2005 * San Francisco, CA * Development Lifecycle Practices > Agile & Plan-Driven Development * Managing Projects & Teams * Testing & QA > Security * Process Improvement & Measurement * http://www.sqe.com/bsce5sf > _______________________________________________ > Bacula-users mailing list > Bacula-users@lists.sourceforge.net > https://lists.sourceforge.net/lists/listinfo/bacula-users ------------------------------------------------------- SF.Net email is Sponsored by the Better Software Conference & EXPO September 19-22, 2005 * San Francisco, CA * Development Lifecycle Practices Agile & Plan-Driven Development * Managing Projects & Teams * Testing & QA Security * Process Improvement & Measurement * http://www.sqe.com/bsce5sf _______________________________________________ Bacula-users mailing list Bacula-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bacula-users