Hi Christopher,
I'm not sure I understand your question.
What I have set up for testing SS7 is as follows :-
SS7 Linkset 1 comes out of TE410P span 1, via a T1/E1 crossover cable
into span 2 of the same TE410P to SS7 Linkset 2
Regards
Mark.
Christopher Srinivasa wrote:
How were you able to go from two SS7 linksets into the TE410P E1 card
to a single ISDN after conversion on the crossover link?
Did you not have traffic congestion problems when going from 2 to 1 ?
Unless an SS7 linkset is equivalent to half an E1 ?
------------------------------------------------------------------------