Use a pro power box, seems to be flawless instead of the base having random
weird issues

Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373

On Tue, Jan 28, 2020, 1:05 PM Mathew Howard <mhoward...@gmail.com> wrote:

> Yeah, that might work, but that's just going to be putting both SM's on
> the same layer 2 network anyway... it'd be simpler/cheaper to just throw a
> MikroTik PowerBox up there, if that's acceptable.
>
> On Tue, Jan 28, 2020 at 11:55 AM Ken Hohhof <af...@kwisp.com> wrote:
>
>> Is this ePMP or 450?  I wonder if you could enable POE out on the AUX
>> port of a 450i SM to run a second SM?  Multiple problems, like 450i SM
>> needs 48V, plus Cambium never talks about using the AUX port for another SM
>> but rather for things like cameras.  I’m not sure if the AUX port POE out
>> is 48 or 24 volts.  Plus the 450i SM is hideously expensive.
>>
>>
>>
>>
>>
>> *From:* AF <af-boun...@af.afmug.com> *On Behalf Of *Carl Peterson
>> *Sent:* Tuesday, January 28, 2020 11:45 AM
>> *To:* AnimalFarm Microwave Users Group <af@af.afmug.com>
>> *Subject:* Re: [AFMUG] Cambium POE Splitter
>>
>>
>>
>> I've never done it, but UBNT has some gigabit 24V A+B POE injectors for
>> AirFiber.  You should just be able to split it out on both sides so A POE
>> powers one and B POE powers the other.  If the topside devices cant take
>> power on the data pins, you would need to pick the power off with gigabit
>> power taps and put it back onto the power pins.  Much (1000X) easier to
>> just use a Netonxi 6 min in one of their little plastic od enclosures.
>>
>>
>>
>> On Tue, Jan 28, 2020 at 11:32 AM Mathew Howard <mhoward...@gmail.com>
>> wrote:
>>
>> There are ways you could do power on two pairs... might not be very
>> pretty, but it can certainly be done.
>>
>> It's hard to say what would be the best way to do it, without knowing
>> exactly what we're trying to accomplish.
>>
>>
>>
>>
>>
>> On Tue, Jan 28, 2020 at 10:30 AM Jason McKemie <
>> j.mcke...@veloxinetbroadband.com> wrote:
>>
>> You can do fast Ethernet with 2 pair, I'm not aware of a way to send
>> power up there as well, however.
>>
>> On Tuesday, January 28, 2020, Matt <matt.mailingli...@gmail.com> wrote:
>>
>> I have a case where I need to power up two separate Cambium 24 volt
>> SMs on rooftop but only need 100base to each.  Its very difficult to
>> run the second wire at this location which I need.  Anyone know of way
>> to split the cat5 at bottom and top to do this?  Not likely but
>> thought I would ask.
>>
>> --
>> AF mailing list
>> AF@af.afmug.com
>> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
>>
>> --
>> AF mailing list
>> AF@af.afmug.com
>> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
>>
>> --
>> AF mailing list
>> AF@af.afmug.com
>> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
>>
>>
>>
>>
>> --
>>
>> Carl Peterson
>>
>> *PORT NETWORKS*
>>
>> 401 E Pratt St, Ste 2553
>>
>> Baltimore, MD 21202
>>
>> (410) 637-3707
>> --
>> AF mailing list
>> AF@af.afmug.com
>> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
>>
> --
> AF mailing list
> AF@af.afmug.com
> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
>
-- 
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

Reply via email to