My advice would be You should upgrade to a suuported version of TSM. If you cannot do this then :-
1) Make sure you are on the latest available fix levels for your version of ADSM 2) Try to keep other ADSM activity to a minimum when running your database backup "Ramnarayan, Sean A [EDS]" <[EMAIL PROTECTED]> on 02/22/2002 07:18:23 AM Please respond to "ADSM: Dist Stor Manager" <[EMAIL PROTECTED]> To: [EMAIL PROTECTED] cc: (bcc: John Naylor/HAV/SSE) Subject: Re: ADSM/TSM ERROR Message Hi We are currently on version 3.1.2.50 adsm server code and 3.1.20.7 client code. We do not have support from IBM as ADSM V3 has been discontinued. The processes that where running was a Level 0 backup of Informix using the API client code. The ADSM database backup a Full Backup was running at the same time and a few copy storage pool jobs. Thks Sean Ramnarayan -----Original Message----- From: John Naylor [mailto:[EMAIL PROTECTED]] Sent: Thursday, February 21, 2002 5:20 PM To: [EMAIL PROTECTED] Subject: Re: ADSM/TSM ERROR Message This type of error is normally a problem to raise with TSM support. There are quite a few hits for anr7834s It would help the list if you indicated what TSM processes were active at the time of the crash. Your TSM level and the server operating system would also be good. "Ramnarayan, Sean A [EDS]" <[EMAIL PROTECTED]> on 02/21/2002 01:59:22 PM Please respond to "ADSM: Dist Stor Manager" <[EMAIL PROTECTED]> To: [EMAIL PROTECTED] cc: (bcc: John Naylor/HAV/SSE) Subject: ADSM/TSM ERROR Message Hi The below error caused the adsm/tsm application to crash. Has anyone seen this error before and please could you explain what caused the error : 1020221-114111: ANR7834S Thread 52 (tid 3436) terminating on signal 11 (Segment ation violation). 1020221-114111: ANR7834S GPR 0: 0x309ab364, 1: 0x35333110, 2: 0x30109290, 3: 0x339677c4 1020221-114111: ANR7834S GPR 4: 0x00000001, 5: 0x34d1c944, 6: 0x00000000, 7: 0x00370a97 1020221-114111: ANR7834S GPR 8: 0x00000000, 9: 0x00000000, 10: 0x00000001, 11: 0x000034e0 1020221-114111: ANR7834S GPR 12: 0x00000000, 13: 0x3000e230, 14: 0x30005544, 15: 0x30945a00 1020221-114111: ANR7834S GPR 16: 0x00000007, 17: 0x3000d8e4, 18: 0x00000000, 19: 0x3000d8ec 1020221-114111: ANR7834S GPR 20: 0x309457b4, 21: 0x3000d8fc, 22: 0x00000000, 23: 0x3000d904 1020221-114111: ANR7834S GPR 24: 0x3000d8a0, 25: 0x3000d8b8, 26: 0x3000d8b0, 27: 0x00000001 1020221-114111: ANR7834S GPR 28: 0x33967818, 29: 0x339677c4, 30: 0x00000003, 31: 0x30945a30 1020221-114111: ANR7834S IAR: 0x100461fc, LR: 0x1004707c, CONTEXT: 0x35332d90 1020221-114111: 0x100461FC AddList 1020221-114111: 0x10005F14 StartThread 1020221-114111: 0xD04AD234 _pthread_body 1020221-114111: ANR7833S ADSM thread 1 terminated in response to program abort. 1020221-114111: ANR7833S ADSM thread 2 terminated in response to program abort. 1020221-114111: ANR7833S ADSM thread 3 terminated in response to program abort. 1020221-114111: ANR7833S ADSM thread 4 terminated in response to program abort. 1020221-114111: ANR7833S ADSM thread 5 terminated in response to program abort. 1020221-114111: ANR7833S ADSM thread 6 terminated in response to program abort. 1020221-114111: ANR7833S ADSM thread 7 terminated in response to program abort. 1020221-114152: DSMULOG Terminating. Thks Sean Ramnarayan "MMS <caltex.com>" made the following annotations on 02/21/2002 03:59:23 PM ------------------------------------------------------------------------ ------ DISCLAIMER This message may contain confidential information that is legally privileged and is intended only for the use of the parties to whom it is addressed. If you are not an intended recipient, you are hereby notified that any disclosure, copying, distribution or use of any information in this message is strictly prohibited. If you have received this message in error, please notify the sender immediately and delete the message. Thank you. ======================================================================== ====== ********************************************************************** The information in this E-Mail is confidential and may be legally privileged. It may not represent the views of Scottish and Southern Energy plc. It is intended solely for the addressees. Access to this E-Mail by anyone else is unauthorised. If you are not the intended recipient, any disclosure, copying, distribution or any action taken or omitted to be taken in reliance on it, is prohibited and may be unlawful. Any unauthorised recipient should advise the sender immediately of the error in transmission. Scottish Hydro-Electric, Southern Electric, SWALEC and S+S are trading names of the Scottish and Southern Energy Group. ********************************************************************** "MMS <caltex.com>" made the following annotations on 02/22/2002 09:18:23 AM ------------------------------------------------------------------------------ DISCLAIMER This message may contain confidential information that is legally privileged and is intended only for the use of the parties to whom it is addressed. If you are not an intended recipient, you are hereby notified that any disclosure, copying, distribution or use of any information in this message is strictly prohibited. If you have received this message in error, please notify the sender immediately and delete the message. Thank you. ==============================================================================