----- Original Message -----
> hi all
> 
> I had a 7-VDEV raid on some drives, and after rearranging them a bit
<snip/>

11-vdev, even, but the problem was fm had stepped in and found something was 
wrong with c8t35d0. To fix this, I did:

# fmadm repaired 
hc://:product-id=LSI-CORP-SAS2X28:server-id=:chassis-id=50030480009a4c7f:serial=WD-WMAY00247950:part=WDC-WD2001FASS-00W2B0:revision=05.01D05/ses-enclosure=3/bay=11/disk=0
# zpool remove pbpool c8t35d0
# zpool add pbpool spare c8t35d0

Done - works

Vennlige hilsener / Best regards

roy
--
Roy Sigurd Karlsbakk
(+47) 97542685
r...@karlsbakk.net
http://blogg.karlsbakk.net/
--
I all pedagogikk er det essensielt at pensum presenteres intelligibelt. Det er 