On Wed, Oct 20, 2010 at 4:05 PM, Edward Ned Harvey <sh...@nedharvey.com> wrote: >> From: zfs-discuss-boun...@opensolaris.org [mailto:zfs-discuss- >> boun...@opensolaris.org] On Behalf Of Edward Ned Harvey >> >> 4. Guess what happens if you have 2 or 3 failed disks in your raidz3, >> and >> they're trying to resilver at the same time. Does the system ignore >> subsequently failed disks and concentrate on restoring a single disk >> quickly? Or does the system try to resilver them all simultaneously >> and >> therefore double or triple the time before any one disk is fully >> resilvered? > > This is a legitimate question. If anyone knows, I'd like to know... >
My recent experience with os_111b, os_134 and oi_147 was that subsequent failure and disk replacement causes resilver to restart from beginning, including the new disks on the later pass. If disk is not replaced, the resilver would run to completion (and then a replace could be performed with a new resilver). This however is an issue that is being developed further so changes may be coming. -- - Tuomas _______________________________________________ zfs-discuss mailing list zfs-discuss@opensolaris.org http://mail.opensolaris.org/mailman/listinfo/zfs-discuss