On Aug 5, 2010, at 11:10 AM, Roch <roch.bourbonn...@sun.com> wrote:

> 
> Ross Walker writes:
>> On Aug 4, 2010, at 12:04 PM, Roch <roch.bourbonn...@sun.com> wrote:
>> 
>>> 
>>> Ross Walker writes:
>>>> On Aug 4, 2010, at 9:20 AM, Roch <roch.bourbonn...@sun.com> wrote:
>>>> 
>>>>> 
>>>>> 
>>>>> Ross Asks: 
>>>>> So on that note, ZFS should disable the disks' write cache,
>>>>> not enable them  despite ZFS's COW properties because it
>>>>> should be resilient. 
>>>>> 
>>>>> No, because ZFS builds resiliency on top of unreliable parts. it's able 
>>>>> to deal
>>>>> with contained failures (lost state) of the disk write cache. 
>>>>> 
>>>>> It can then export LUNS that have WC enabled or
>>>>> disabled. But if we enable the WC on the exported LUNS, then
>>>>> the consumer of these LUNS must be able to say the same.
>>>>> The discussion at that level then needs to focus on failure groups.
>>>>> 
>>>>> 
>>>>> Ross also Said :
>>>>> I asked this question earlier, but got no answer: while an
>>>>> iSCSI target is presented WCE does it respect the flush
>>>>> command? 
>>>>> 
>>>>> Yes. I would like to say "obviously" but it's been anything
>>>>> but.
>>>> 
>>>> Sorry to probe further, but can you expand on but...
>>>> 
>>>> Just if we had a bunch of zvols exported via iSCSI to another Solaris
>>>> box which used them to form another zpool and had WCE turned on would
>>>> it be reliable? 
>>>> 
>>> 
>>> Nope. That's because all the iSCSI are in the same fault
>>> domain as they share a unified back-end cache. What works,
>>> in principle, is mirroring SCSI channels hosted on 
>>> different storage controllers (or N SCSI channels on N
>>> controller in a raid group).
>>> 
>>> Which is why keeping the WC set to the default, is really
>>> better in general.
>> 
>> Well I was actually talking about two backend Solaris storage servers 
>> serving up storage over iSCSI to a front-end Solaris server serving ZFS over 
>> NFS, so I have redundancy there, but want the storage to be performant, so I 
>> want the iSCSI to have WCE, yet I want it to be reliable and have it honor 
>> cache flush requests from the front-end NFS server.
>> 
>> Does that make sense? Is it possible?
>> 
> 
> Well in response to a commit (say after a file creation) then the
> front end server will end up sending flush write caches on
> both side of the iscsi mirror which will reach the backend server
> which will flush disk write caches. This will all work but
> probably  not unleash performance the way you would like it
> to.



> If you setup to have the backend server not honor the
> backend disk flush write caches, then the 2 backend pools become at
> risk of corruption, mostly because the ordering of IOs
> around the ueberblock updates. If you have faith, then you
> could consider that you won't hit 2 backend pool corruption
> together and rely on the frontend resilvering to rebuild the
> corrupted backend.

So you are saying setting WCE disables cache flush on the target and setting 
WCD forces a flush for every WRITE?

How about a way to enable WCE on the target, yet still perform cache flush when 
the initiator requests one, like a real SCSI target should do, or is that just 
not possible with ZVOLs today?