On Wed, Feb 24, 2010 at 10:57:08AM +0000, li...@di.cx wrote:
> 2 x SuperMicro AOC-SAT2-MV8 SATA controllers (so 16 ports in total,
> plus 6 on the motherboard)

What about case space for the disks?

> Disks: 3x40GB

rpool mirror and spare on shelf.  3 way mirror if you really want and have the 
space.

> 1x250GB

single pool, scratch space and adhoc backups, or hurl it at the
invading barbarian horde, as you prefer.  

> 4x500GB

2+2 mirror, one mirror side on each AOC card, for vm images and documents.

> 4x1TB 

buy 2 more, 6-way raidz2 for misc media, 3 ports each per AOC.  do
automated regular send|recv of the 4x500 pool onto this one as backup.

> and looking to buy some 2TB disks to fill the gap (unless advised against 
> here)

hold off on these.  when you need future expansion, get 6 of whatever
disk makes sense at the time.  you have 6 ports left on your AOCs, so
you can add a second 6-way raidz2 vdev to the above pool, or
upgrade-in-place the 1Tb drives in that pool.

This leaves you 3 or 4 motherboard ports (depending what you do with
the 250) to use for zil or l2arc ssd's.  This, or more RAM if the m/b
will take it, is a better use of your cash now.

--
Dan.

Attachment: pgpuHX7EJkJFE.pgp
Description: PGP signature

_______________________________________________
zfs-discuss mailing list
zfs-discuss@opensolaris.org
http://mail.opensolaris.org/mailman/listinfo/zfs-discuss

Reply via email to