I would get a new 1.5 TB and make sure it has the new firmware and replace c6t3d0 right away - even if someone here comes up with a magic solution, you don't want to wait for another drive to fail.
http://hardware.slashdot.org/article.pl?sid=09/01/17/0115207 http://techreport.com/discussions.x/15863 Brad Hill wrote: > Sure, and thanks for the quick reply. > > Controller: Supermicro AOC-SAT2-MV8 plugged into a 64-big PCI-X 133 bus > Drives: 5 x Seagate 7200.11 1.5TB disks for the raidz1. > Single 36GB western digital 10krpm raptor as system disk. Mate for this is in > but not yet mirrored. > Motherboard: Tyan Thunder K8W S2885 (Dual AMD CPU) with 1GB ECC Ram > > Anything else I can provide? > > (thanks again) _______________________________________________ zfs-discuss mailing list zfs-discuss@opensolaris.org http://mail.opensolaris.org/mailman/listinfo/zfs-discuss