On Tue, Jun 10, 2008 at 8:01 AM, Ben Middleton <[EMAIL PROTECTED]> wrote: > Today's findings are that the cksum errors appear on the new disk on the > other controller too - so I've ruled out controllers & cables. It's probably > as Jeff says - just got to figure out now how to prove the memory is duff.
How much memory do you have and what chipset / controller are you using? There are some controllers that claim to do DMA to 64-bit addresses but don't actually support it, which causes errors on machines with > 4gb of memory. The SB600 is one example. If it is bad memory that has somehow passed memtest, swapping the memory for known good (preferably ECC) memory is one option to diagnose it. -B -- Brandon High [EMAIL PROTECTED] "The good is the enemy of the best." - Nietzsche _______________________________________________ zfs-discuss mailing list zfs-discuss@opensolaris.org http://mail.opensolaris.org/mailman/listinfo/zfs-discuss