Question #702133 on Yade changed: https://answers.launchpad.net/yade/+question/702133
Robert Caulk proposed the following answer: Hey Zoheir, Yes, this is why I started by asking if your pressure and temperature are non-linearly related (are they?). If they are linearly related, then the existing weak coupling in ThermalEngine is perfectly adequate. >> What do you think? In the case that they are linearly related, I do not understand why you would modify anything. ThermalEngine is already doing what you need, as you found. Beta is the coefficient of thermal expansion which has units of (1/v) * (dv/dT). Dividing the entire expression by temperature as you are doing makes little sense to me. Perhaps you can explain your rationale? -rc -- You received this question notification because your team yade-users is an answer contact for Yade. _______________________________________________ Mailing list: https://launchpad.net/~yade-users Post to : yade-users@lists.launchpad.net Unsubscribe : https://launchpad.net/~yade-users More help : https://help.launchpad.net/ListHelp