Hi,

Please find attached little changes in capillary law2 doc, to better explain 
the behavior of the fusionDetection. I plan to commit if there is no objection




diff --git a/pkg/dem/Law2_ScGeom_CapillaryPhys_Capillarity.hpp 
b/pkg/dem/Law2_ScGeom_CapillaryPhys_Capillarity.hpp
index 5363c62..e391482 100644
--- a/pkg/dem/Law2_ScGeom_CapillaryPhys_Capillarity.hpp
+++ b/pkg/dem/Law2_ScGeom_CapillaryPhys_Capillarity.hpp
@@ -87,8 +87,8 @@ class Law2_ScGeom_CapillaryPhys_Capillarity : public 
GlobalEngine
                
        
YADE_CLASS_BASE_DOC_ATTRS_DEPREC_INIT_CTOR_PY(Law2_ScGeom_CapillaryPhys_Capillarity,GlobalEngine,"This
 law allows one to take into account capillary forces/effects between spheres 
coming from the presence of interparticular liquid bridges (menisci).\n\nThe 
control parameter is the :yref:`capillary 
pressure<Law2_ScGeom_CapillaryPhys_Capillarity::capillaryPressure>` (or 
suction) Uc = Ugas - Uliquid. Liquid bridges properties (volume V, extent over 
interacting grains delta1 and delta2) are computed as a result of the defined 
capillary pressure and of the interacting geometry (spheres radii and 
interparticular distance).\n\nReferences: in english [Scholtes2009b]_; more 
detailed, but in french [Scholtes2009d]_.\n\nThe law needs ascii files M(r=i) 
with i=R1/R2 to work (see https://yade-dem.org/wiki/CapillaryTriaxialTest). 
These ASCII files contain a set of results from the resolution of the 
Laplace-Young equation for different configurations of the interacting 
geometry, assuming a null wetting angle.\n\nIn order to allow capillary forces 
between distant spheres, it is necessary to enlarge the bounding boxes using 
:yref:`Bo1_Sphere_Aabb::aabbEnlargeFactor` and make the Ig2 define define 
distant interactions via 
:yref:`interactionDetectionFactor<Ig2_Sphere_Sphere_ScGeom::interactionDetectionFactor>`.
 It is also necessary to disable interactions removal by the constitutive law 
(:yref:`Law2<Law2_ScGeom_FrictPhys_CundallStrack::neverErase>=True`). The only 
combinations of laws supported are currently capillary law + 
:yref:`Law2_ScGeom_FrictPhys_CundallStrack` and capillary law + 
:yref:`Law2_ScGeom_MindlinPhys_Mindlin` (and the other variants of 
Hertz-Mindlin).\n\nSee CapillaryPhys-example.py for an example script.",
        ((Real,capillaryPressure,0.,,"Value of the capillary pressure Uc 
defined as Uc=Ugas-Uliquid"))
-       ((bool,fusionDetection,false,,"If true potential menisci overlaps are 
checked"))
-       ((bool,binaryFusion,true,,"If true, capillary forces are set to zero as 
soon as, at least, 1 overlap (menisci fusion) is detected"))
+       ((bool,fusionDetection,false,,"If true potential menisci overlaps are 
checked, computing :yref:`fusionNumber<CapillaryPhys.fusionNumber>` for each 
capillary interaction, and reducing :yref:`fCap<CapillaryPhys.fCap>` according 
to :yref:`binaryFusion<Law2_ScGeom_CapillaryPhys_Capillarity.binaryFusion>`"))
+       ((bool,binaryFusion,true,,"If true, capillary forces are set to zero as 
soon as, at least, 1 overlap (menisci fusion) is detected. Otherwise 
:yref:`fCap<CapillaryPhys.fCap>` = :yref:`fCap<CapillaryPhys.fCap>` / 
(:yref:`fusionNumber<CapillaryPhys.fusionNumber>` + 1 )"))
        ((bool,hertzOn,false,,"|yupdate| true if hertz model is used"))
        ((bool,createDistantMeniscii,false,,"Generate meniscii between distant 
spheres? Else only maintain the existing ones. For modeling a wetting path this 
flag should always be false. For a drying path it should be true for one step 
(initialization) then false, as in the logic of [Scholtes2009c]_"))
         ((Real,surfaceTension,0.073,,"Value of considered surface tension"))
_______________________________________________
Mailing list: https://launchpad.net/~yade-dev
Post to     : [email protected]
Unsubscribe : https://launchpad.net/~yade-dev
More help   : https://help.launchpad.net/ListHelp