On 03/09/2024 3:26 pm, Jan Beulich wrote:
> On 03.09.2024 16:19, Andrew Cooper wrote:
>> SBI has an API for shutdown so wire it up.  However, the spec does allow the
>> call not to be implemented, so we have to cope with the call return 
>> returning.
>>
>> There is a reboot-capable SBI extention, but in the short term route route
>> machine_restart() into machine_halt().
>>
>> Then, use use machine_halt() rather than an infinite loop at the end of
>> start_xen().  This avoids the Qemu smoke test needing to wait for the full
>> timeout in order to succeed.
>>
>> Signed-off-by: Andrew Cooper <andrew.coop...@citrix.com>
> Acked-by: Jan Beulich <jbeul...@suse.com>

Thanks.

> ideally with ...
>
>> --- /dev/null
>> +++ b/xen/arch/riscv/shutdown.c
>> @@ -0,0 +1,25 @@
>> +/* SPDX-License-Identifier: GPL-2.0-or-later */
>> +#include <xen/shutdown.h>
>> +
>> +#include <asm/sbi.h>
>> +
>> +void machine_halt(void)
>> +{
>> +    sbi_shutdown();
>> +
>> +    for ( ;; )
>> +        asm volatile ("wfi");
> ... the missing blanks added here, as you move that loop around.

Ah yes.  Will do.

~Andrew

Reply via email to