When entering the hypervisor via the double fault handler resetting
xen_cr3 was missing. This led to switching to pv_cr3 when returning
from the next following interrupt. So repair this in order to allow
interrupt handling to work even after a double fault.
Signed-off-by: Juergen Gross <jgr...@suse.com>
---
xen/arch/x86/x86_64/entry.S | 1 +
1 file changed, 1 insertion(+)
diff --git a/xen/arch/x86/x86_64/entry.S b/xen/arch/x86/x86_64/entry.S
index 45d9842d09..25427b0cec 100644
--- a/xen/arch/x86/x86_64/entry.S
+++ b/xen/arch/x86/x86_64/entry.S
@@ -773,6 +773,7 @@ ENTRY(double_fault)
neg %rbx
.Ldblf_cr3_load:
mov %rbx, %cr3
+ movq $0, STACK_CPUINFO_FIELD(xen_cr3)(%r14)
.Ldblf_cr3_okay:
movq %rsp,%rdi
--
2.13.6