Subject: Re: ARM Xen Bug #45: Is there a solution?
Date: Tue, 31 May 2016 11:44:23 +0100
From: Julien Grall <julien.gr...@arm.com>
To: Dirk Behme <dirk.be...@gmail.com>, xen-devel@lists.xen.org
<xen-devel@lists.xen.org>
CC: Stefano Stabellini <sstabell...@kernel.org>, Ian Jackson
<ian.jack...@eu.citrix.com>

Hello Dirk,

On 27/05/16 13:34, Dirk Behme wrote:
On 26.05.2016 11:00, Julien Grall wrote:
On 25/05/2016 16:10, Dirk Behme wrote:
On 24.05.2016 22:05, Julien Grall wrote:
On 24/05/2016 14:39, Dirk Behme wrote:
On 23.05.2016 22:15, Julien Grall wrote:
All the devices (UART included) used by Xen will return DOMID_XEN when
dt_device_used_by is called to the node.

You could use it to collect the clocks of all those devices and gather
the value in a single property to be created in the hypervisor node.


Anything like below (untested) [1]?

Yes.

I'm unhappy about the global variables and the max clocks, though.

How about moving those variables in the structure kernel_info?


Just for the logs to finish this thread:

https://lists.xen.org/archives/html/xen-devel/2016-06/msg02607.html

http://lists.infradead.org/pipermail/linux-arm-kernel/2016-June/438067.html


Best regards

Dirk


_______________________________________________
Xen-devel mailing list
Xen-devel@lists.xen.org
http://lists.xen.org/xen-devel

Reply via email to