>>> On 28.09.17 at 12:16, <dario.faggi...@citrix.com> wrote: > Basically, if the RCU idle timer, when (if!) it fires, > finds that the grace period isn't over, we increase the > timer's period (i.e., it will fire later, next time). > If, OTOH, it finds the grace period is already finished, > we decrease the timer's period (i.e., it will fire a bit > earlier next time). > > The goal is to let the period timer sefl-adjust to a > number of 'misses', of the order of 1%. > > Signed-off-by: Dario Faggioli <dario.faggi...@citrix.com> > Suggested-by: George Dunlap <george.dun...@citrix.com>
Reviewed-by: Jan Beulich <jbeul...@suse.com> _______________________________________________ Xen-devel mailing list Xen-devel@lists.xen.org https://lists.xen.org/xen-devel