On your build definition, what is your setting for "MSBuild Platform"?

--
John Merryweather Cooper
Senior Software Engineer | Enterprise Service Applications | Continuing 
Development
Jack Henry & Associates, Inc.® | Lenexa, KS  66214 | Ext:  431050 
|jocoo...@jackhenry.com



-----Original Message-----
From: Farrukhw [mailto:farru...@gmail.com] 
Sent: Wednesday, September 24, 2014 8:28 AM
To: wix-users@lists.sourceforge.net
Subject: [WiX-users] HeatDirectory failure on TFS

Hi experts,
I'm using HeatDirectory task in my *.wixproj file, which is working very fine 
on my machine, being built locally.

However, on TFS, it is failing with following error:

C:\Program Files (x86)\WiX Toolset v3.8\bin\Heat.exe dir 
D:\Builds\32\48\bin\Debug\InstallSrc\WebApp\ -cg CompGrp_WebApp -dr WebApp -ke 
-scom -sreg -srd -var var.WebAppSrc -v -ag -sfrag -suid -out WebApp_.wxs
         Could not load file or assembly 'file:///C:\Program Files (x86)\WiX 
Toolset v3.8\bin\Heat.exe' or one of its dependencies. An attempt was made to 
load a program with an incorrect format.
            at System.Reflection.RuntimeAssembly._nLoad(AssemblyName
fileName, String codeBase, Evidence assemblySecurity, RuntimeAssembly 
locationHint, StackCrawlMark& stackMark, IntPtr pPrivHostBinder, Boolean 
throwOnFileNotFound, Boolean forIntrospection, Boolean
suppressSecurityChecks)
            at
System.Reflection.RuntimeAssembly.InternalLoadAssemblyName(AssemblyName
assemblyRef, Evidence assemblySecurity, RuntimeAssembly reqAssembly, 
StackCrawlMark& stackMark, IntPtr pPrivHostBinder, Boolean throwOnFileNotFound, 
Boolean forIntrospection, Boolean
suppressSecurityChecks)
            at
System.Reflection.RuntimeAssembly.InternalLoadAssemblyName(AssemblyName
assemblyRef, Evidence assemblySecurity, RuntimeAssembly reqAssembly, 
StackCrawlMark& stackMark, Boolean throwOnFileNotFound, Boolean 
forIntrospection, Boolean suppressSecurityChecks)
            at System.Reflection.RuntimeAssembly.InternalLoadFrom(String
assemblyFile, Evidence securityEvidence, Byte[] hashValue, 
AssemblyHashAlgorithm hashAlgorithm, Boolean forIntrospection, Boolean 
suppressSecurityChecks, StackCrawlMark& stackMark)
            at System.Reflection.Assembly.LoadFrom(String assemblyFile)
            at
Microsoft.Tools.WindowsInstallerXml.Build.Tasks.WixToolTask.ExecuteToolThread(Object
parameters)
     0>MSBUILD : error MSB4166: Child node "3" exited prematurely. Shutting 
down. Diagnostic information may be found in files in the temporary files 
directory named MSBuild_*.failure.txt.


However, on same build machine, I tried to execute heat command line (generated 
by above log) and got it working fine: i.e.
C:\Program Files (x86)\WiX Toolset v3.8\bin\Heat.exe dir 
D:\Builds\32\48\bin\Debug\InstallSrc\WebApp\ -cg CompGrp_WebApp -dr WebApp -ke 
-scom -sreg -srd -var var.WebAppSrc -v -ag -sfrag -suid -out WebApp_.wxs



I even tried it, by disabling MsBuild Multi-Proc (building projects in
parallel) in TFS definition, but in vain.

Why it is failing on TFS, but not locally?

Thanks a bunch.....





--
View this message in context: 
http://windows-installer-xml-wix-toolset.687559.n2.nabble.com/HeatDirectory-failure-on-TFS-tp7596956.html
Sent from the wix-users mailing list archive at Nabble.com.

------------------------------------------------------------------------------
Meet PCI DSS 3.0 Compliance Requirements with EventLog Analyzer Achieve PCI DSS 
3.0 Compliant Status with Out-of-the-box PCI DSS Reports Are you Audit-Ready 
for PCI DSS 3.0 Compliance? Download White paper Comply to PCI DSS 3.0 
Requirement 10 and 11.5 with EventLog Analyzer 
http://pubads.g.doubleclick.net/gampad/clk?id=154622311&iu=/4140/ostg.clktrk
_______________________________________________
WiX-users mailing list
WiX-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wix-users
NOTICE: This electronic mail message and any files transmitted with it are 
intended
exclusively for the individual or entity to which it is addressed. The message, 
together with any attachment, may contain confidential and/or privileged 
information.
Any unauthorized review, use, printing, saving, copying, disclosure or 
distribution 
is strictly prohibited. If you have received this message in error, please 
immediately advise the sender by reply email and delete all copies.


------------------------------------------------------------------------------
Meet PCI DSS 3.0 Compliance Requirements with EventLog Analyzer
Achieve PCI DSS 3.0 Compliant Status with Out-of-the-box PCI DSS Reports
Are you Audit-Ready for PCI DSS 3.0 Compliance? Download White paper
Comply to PCI DSS 3.0 Requirement 10 and 11.5 with EventLog Analyzer
http://pubads.g.doubleclick.net/gampad/clk?id=154622311&iu=/4140/ostg.clktrk
_______________________________________________
WiX-users mailing list
WiX-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wix-users

Reply via email to