Hi all,
I'm currently trying to put together an installer which will deploy 4 Web Applications to a set of servers. This means there are 4 separate Web Application directories with 4 separate (and different) versions of the Web.config file. I'm using Heat to generate the .wxs files for the Web Applications, however it only appears to be giving each instance of the Web.config <File> the Source="SourceDir\Web.config", which I believe is resulting in only the first Web.config being used for each of the Web Applications (which is causing the other three to not work). I'm also using Visual Studio 2012, and Votive (I believe..). So I've got the following at the end of my .wixproj file . <Import Project="$(WixTargetsPath)" /> <Target Name="BeforeBuild"> <MSBuild Projects="%(ProjectReference.FullPath)" Targets="Package" Properties="Configuration=$(Configuration);Platform=AnyCPU" Condition="'%(ProjectReference.WebProject)'=='True'" /> <ItemGroup> <LinkerBindInputPaths Include="%(ProjectReference.RootDir)%(ProjectReference.Directory)obj\$(Confi guration)\Package\PackageTmp\" /> </ItemGroup> <PropertyGroup> <DefineConstants Condition="'%(ProjectReference.WebProject)'=='True'"> $(DefineConstants);%(ProjectReference.Name).PackageDir=%(ProjectReference.Ro otDir)%(ProjectReference.Directory)obj\$(Configuration)\Package\PackageTmp\ </DefineConstants> </PropertyGroup> <HeatDirectory OutputFile="%(ProjectReference.Filename).wxs" Directory="%(ProjectReference.RootDir)%(ProjectReference.Directory)obj\$(Con figuration)\Package\PackageTmp" DirectoryRefId="%(ProjectReference.RefTargetDir)" ComponentGroupName="%(ProjectReference.Filename)_Project" AutogenerateGuids="true" SuppressCom="true" SuppressFragments="true" SuppressRegistry="true" SuppressRootDirectory="true" PreprocessorVariable="wix.%(ProjectReference.Name).PackageDir=%(ProjectRefer ence.RootDir)%(ProjectReference.Directory)obj\$(Configuration)\Package\Packa geTmp" ToolPath="$(WixToolPath)" Condition="'%(ProjectReference.WebProject)'=='True'" /> </Target> </Project> The PreprocessorVariable stuff on the HeatDirectory action is my attempt at fixing the issue. However I don't seem to be able to get the DefineConstants working properly (it's only ever assigning one path, not the remaining three). The initial version (which I found via google searches), didn't have any PreprocessorVariable, and had the exact issue I mention above. This new version appears better (has unique Source paths), but doesn't compile because of the lacking Defines. I can attach the actual .wxs file outputs if desired, however I didn't think they would be so beneficial to send just yet. I would have expected others would have come upon this issue before.. Unless it's something that a recent version of WiX has brought up. I'm running v3.7. Any help would be greatly appreciated. Regards, Bevan Weiss ------------------------------------------------------------------------------ How ServiceNow helps IT people transform IT departments: 1. Consolidate legacy IT systems to a single system of record for IT 2. Standardize and globalize service processes across IT 3. Implement zero-touch automation to replace manual, redundant tasks http://pubads.g.doubleclick.net/gampad/clk?id=51271111&iu=/4140/ostg.clktrk _______________________________________________ WiX-users mailing list WiX-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/wix-users