Based on what people said in earlier messages, I'm migrating to using a
wixlib with a fragment generated by Heat.  A lack of samples or useful
documentation had left me doing trial and error to figure how.

If you think that there is a better method, please let me know what it is.
:)

-Jamey
____________________________________________________________
[EMAIL PROTECTED] 

> -----Original Message-----
> From: [EMAIL PROTECTED] [mailto:wix-users-
> [EMAIL PROTECTED] On Behalf Of Bob Arnson
> Sent: Saturday, July 19, 2008 10:22 AM
> To: General discussion for Windows Installer XML toolset.
> Subject: Re: [WiX-users] Merge Module Help
> 
> James Minnis wrote:
> > Right now, I'm generating a merge module
> 
> Do you have a specific need for a merge module? (i.e., are you sharing
> it with others so they can create installers?) If not, avoid merge
> modules. They needlessly complicate things, as you're finding out with #1.
> 
> > 1) I want to create shortcuts to several of the files in the merge
> module.
> > I'm doing this currently in a start menu shortcuts component in the main
> > installer.  However, I cannot figure out how to reference the
> directories in
> > the merge module in the main project (I get an empty string when I try
> to
> > reference them like I do the directories in the main installer project).
> > How do I reference the directories?  Or is there a better way to do
> this?
> >
> 
> You can't. Merge modules are supposed to be self-contained, so if you
> want shortcuts, define them in the merge module. Or don't use merge
> modules.
> 
> > 2) The components in the merge module are generated with GUIDs.  If I
> > regenerate the merge module WXS file using Heat (e.g. if I add files),
> those
> > GUIDs change.  How will this affect patches?  Will the patch recognize
> the
> > files as being the same, or will it consider all of the files changed
> and
> > overwrite everything?  Will I need to add files manually to the merge
> module
> > WXS file to make patching work correctly?
> >
> 
> You won't be able to patch. The WiX approach is to use stable GUIDs
> (heat's -ag switch). But with 7000 files, that's going to cause some
> long pauses during costing.
> 
> --
> sig://boB
> http://joyofsetup.com/
> 
> 
> 
> -------------------------------------------------------------------------
> This SF.Net email is sponsored by the Moblin Your Move Developer's
> challenge
> Build the coolest Linux based applications with Moblin SDK & win great
> prizes
> Grand prize is a trip for two to an Open Source event anywhere in the
> world
> http://moblin-contest.org/redirect.php?banner_id=100&url=/
> _______________________________________________
> WiX-users mailing list
> WiX-users@lists.sourceforge.net
> https://lists.sourceforge.net/lists/listinfo/wix-users


-------------------------------------------------------------------------
This SF.Net email is sponsored by the Moblin Your Move Developer's challenge
Build the coolest Linux based applications with Moblin SDK & win great prizes
Grand prize is a trip for two to an Open Source event anywhere in the world
http://moblin-contest.org/redirect.php?banner_id=100&url=/
_______________________________________________
WiX-users mailing list
WiX-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wix-users

Reply via email to