Yes, there is a QC section in the conf file where you can set min and max values. This is from my .conf
# This section is for quality control checks. If units are not specified, # values must be in the units defined in the StdConvert section. [StdQC] [[MinMax]] barometer = 26, 32.5, inHg pressure = 24, 34.5, inHg outTemp = 0, 120, degree_F On Tue, Aug 15, 2023 at 9:40 AM kufuu <toefu...@gmail.com> wrote: > I have a lacrosse ws2315 that feeds a pi zero-w thru a serial to usb > converter with weewx, that thing throws a real low out temp a couple times > a week, is there anyway to not let weewx record < 5 temps ? > > -- > You received this message because you are subscribed to the Google Groups > "weewx-user" group. > To unsubscribe from this group and stop receiving emails from it, send an > email to weewx-user+unsubscr...@googlegroups.com. > To view this discussion on the web visit > https://groups.google.com/d/msgid/weewx-user/6fd599f3-b93b-416e-a849-d9f9e6c8235dn%40googlegroups.com > <https://groups.google.com/d/msgid/weewx-user/6fd599f3-b93b-416e-a849-d9f9e6c8235dn%40googlegroups.com?utm_medium=email&utm_source=footer> > . > -- Peter Quinn (415)794-2264 -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to weewx-user+unsubscr...@googlegroups.com. To view this discussion on the web visit https://groups.google.com/d/msgid/weewx-user/CAA1SM23nkk%2BzDezoWQpwHAjAnCkpomih8UKw2GJpaoechdB%3D8Q%40mail.gmail.com.