Hmm. I took another look at the code and I see there's a dictionary in units.py. I don't really want to modify the core code if I can avoid it. Is there a way to override the obs_group_dict?
I also see that there are already PM2.5 and PM10 variables defined in group_concentration. I'll take another look at using these rather than rolling my own. On Saturday, May 15, 2021 at 11:00:29 AM UTC-7 [email protected] wrote: > Hi, > > I've built my own air quality meter and I'm hooking it up to Weewx. I'm > abusing the leafTemp1 and leafTemp2 fields to store PM2.5 and PM10 values. > I've customized the Acurite driver to put these into the database. I have > several other non-standard sensors that I added years ago to this driver > and I'm planning on forking the driver as soon as I've done this particular > customization. That's not the problem. > > The problem I'm having is that there's a conversion going on between degC > and degF for my data that's not a temperature. I can't find where the > fields declare what unit group they are part of. I can't find it in the > documentation or through a quick look in the codebase. > > I suppose what I should do is use the new tools to add 2 new fields and > remove the 2 leafTemp fields that I don't think I'd ever use, but I think > it would be easiest to just re-use the leafTemp fields if I change the unit > group. > > Worst come to worst, I have a super klugy solution of doing a degF to degC > conversion in the driver before I save the data, but that's too much a hack > even for me. > > -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion on the web visit https://groups.google.com/d/msgid/weewx-user/62dd2b7f-582a-4922-aff0-3ef5bdf4b82bn%40googlegroups.com.