Hi, Graham Seems like a reasonable thing to do but, no, there is no way at this point. Perhaps the [[Calculations]] section should be expanded to:
[StdWXCalculate] [[Calculations]] aqi = software, record That is, it takes an optional second positional parameter that can be one of 'loop', 'record', or 'both'. The default would be 'both'. On Fri, Dec 18, 2020 at 7:10 AM Graham Eddy <graham.e...@gmail.com> wrote: > my reading of the 4.3.0 source is that [[Calculations]] calculates the > specified xtypes on each loop packet. is there a simple way now, or is it > in plan, to be able to have them calculated for archive records only? > > i do not want to calculate AQI from averaged pollutant values except when > the averages are updated, which for me is at the end of each archive > interval. i have written a data service to call the xtypes each archive > record, but i would prefer StdWXCalculate handled it for me with ‘= > software’ declarations > > -- > You received this message because you are subscribed to the Google Groups > "weewx-user" group. > To unsubscribe from this group and stop receiving emails from it, send an > email to weewx-user+unsubscr...@googlegroups.com. > To view this discussion on the web visit > https://groups.google.com/d/msgid/weewx-user/D43D0E70-13A6-4B6B-905C-F7597C97DE0A%40gmail.com > . > -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to weewx-user+unsubscr...@googlegroups.com. To view this discussion on the web visit https://groups.google.com/d/msgid/weewx-user/CAPq0zEARNBu0cB18MDYiVc0101vw4W9PEcutpJ3ZFvGmYvt8GQ%40mail.gmail.com.