Hello,
I am hoping to get some help getting my weewx to calculate the ET. Right 
now it just records NULL. I've tried uninstalling and reinstalling, and a 
few different settings in the Calculations section of the config file. I 
also tried a few different ways of installing pyephem (like pip2) but that 
didn't seem to work.

I am using:
Hardware: Acurite 01036, Raspberry Pi 3B+ with latest, up-to-date debian 
stretch 9
Database: MariaDB on separate NAS
Weewx version 3.9.1 with pyephem installed
Python/linux experience: beginner

Everything seems to work fine otherwise. My archive table in the mariadb is 
consistently filled with the default data. My default reports seem to work 
fine, although I do think I am getting the default almanac data - it has 
the Celestial sun and moon data only (I don't know if it's supposed to have 
more with pyephem). But ET is always NULL in the table, and is always None 
in the REC portion of weewx's loop:
----
LOOP:   2019-05-16 19:44:58 MDT (1558057498) altimeter: 29.7337613796, 
channel: 3, dateTime: 1558057498, inTemp: 61.16, maxSolarRad: 
126.776693038, outTempBatteryStatus: 0, pressure: 26.24625289, rain: 0.0, 
rain_total: 5.5372, rainRate: 0, rssi: 3, rxCheckPercent: 100.0, 
sensor_battery: 0, sensor_id: 3620, usUnits: 1, windDir: None, windSpeed: 
0.0
LOOP:   2019-05-16 19:45:16 MDT (1558057516) appTemp: 44.4650993723, 
channel: 3, cloudbase: 4814.9980207, dateTime: 1558057516, dewpoint: 
40.4416051149, heatindex: 46.6, humidex: 46.6, maxSolarRad: 125.978094458, 
outHumidity: 79, outTemp: 46.6, outTempBatteryStatus: 0, rainRate: 0, rssi: 
3, rxCheckPercent: 100.0, sensor_battery: 0, sensor_id: 3620, usUnits: 1, 
windchill: 46.6, windDir: None, windSpeed: 0.0
REC:    2019-05-16 19:45:00 MDT (1558057500) altimeter: 29.7337613796, 
appTemp: 44.4650993723, barometer: 29.7849529075, channel: 3.0, cloudbase: 
4814.9980207, dateTime: 1558057500.0, dewpoint: 40.4416051149, ET: None, 
heatindex: 46.6, humidex: 46.6, inTemp: 61.16, interval: 5, maxSolarRad: 
126.68790242, outHumidity: 79.0, outTemp: 46.6, outTempBatteryStatus: 0.0, 
pressure: 26.24625289, rain: 0.0, rain_total: 5.5372, rainRate: 0.0, rssi: 
3.0, rxCheckPercent: 100.0, sensor_battery: 0.0, sensor_id: 3620.0, 
usUnits: 1, windchill: 46.6, windDir: None, windGust: 0.0, windGustDir: 
None, windrun: 0.0, windSpeed: 0.0
----

My current calculation section of the config is as follows:
--
#   This section controls the origin of derived values.

[StdWXCalculate]
    
    [[Calculations]]
        # How to calculate derived quantities.  Possible values are:
        #  hardware        - use the value provided by hardware
        #  software        - use the value calculated by weewx
        #  prefer_hardware - use value provide by hardware if available,
        #                      otherwise use value calculated by weewx
        
        pressure = prefer_hardware
        barometer = prefer_hardware
        altimeter = prefer_hardware
        windchill = prefer_hardware
        heatindex = prefer_hardware
        dewpoint = prefer_hardware
        inDewpoint = prefer_hardware
        rainRate = prefer_hardware
ET = software
maxSolarRad = software
cloudbase = software
humidex = software
appTemp = software
windrun = software
--

Any help or advice would be appreciated.

Thanks!

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To view this discussion on the web visit 
https://groups.google.com/d/msgid/weewx-user/9f0e979c-3237-4355-9527-1646a106fa01%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

Reply via email to