Luc

The BME280 sensor I have is running off slightly. See below:

Vantage Pro2 Console: 29.68
Acurite Console: 29.64
Hamliton Wall Barometer: ~29.69
Rtldavis with BME280wx: 29.72

Do have a BMP280 module laying around, might switch to that to see what the 
differences are after the storms go through the area later tonite.

Rich





On Friday, April 19, 2019 at 1:35:30 PM UTC-4, Luc Heijst wrote:

> On Tuesday, 16 April 2019 23:21:13 UTC-3, rich T wrote:
>>
>> Drivers I'm currently using are:
>> bme280wx ---- https://gitlab.com/wjcarpenter/bme280wx
>>
>> Rich,
>
> I followed the instructions for my BMP280 sensor in your link because 
> WJCarpenter wrote in the release notes of bme280wx: "This interface seems 
> to work correctly for a BMP280 as well" 
>
> I did gave it a try and I think WJCarpenter is wrong. The pressure 
> readings I get from my BMP280 sensor are way higher than my other preasure 
> readings, see table below.
>
> Vantage Pro console:    1009.23794422608
> Meteostick:             1009.266
> Weather365 Wetterbox:   1010.935
> Rtldavis with BME280wx: 1013.28862385024
>
> BTW. The BMP280 module has I2C address 0x77, so I had to change that in 
> the BME280 setting.
>
> So, work to do to find a better BMP280 driver.
>
> Luc 
>

-- 
You received this message because you are subscribed to the Google Groups 
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
For more options, visit https://groups.google.com/d/optout.