Thanks Haiko… 

we much appreciate the time you took to post this report!

-Mark Iverson

 

From: [email protected] [mailto:[email protected]] 
Sent: Sunday, September 09, 2012 1:02 AM
To: [email protected]; [email protected]
Subject: [Vo]:ECat convention (Report day 1)

 

Report from day 1 of the ECat Convention in Zürich

Andrea Rossi presented a report by „independent parties“ („professors of 
universities“ and „engineers from military environments“), signed by nuclear 
engineer Fabio Penon. All parties that participated in the report are still 
operating to complete their analyses and operations. The document will soon be 
online. Here's a few things I noted:

- The classic ecat is stable at low temperature. „it has been safety certified 
from SGS for all Europe“. But applications require hot temperatures: the „hot 
cat“
- hot cat: analysts were allowed to dismantle the whole reactor system before 
and after operation. Rossi said he was only a observer and did not operate the 
system. But Fulvio Fabiani operated the security and control systems, as the 
report states.
- It's problematic to store hydrogen in such a system (especially if you want 
to receive a safety certificate). Therefore, they had to develop a storage 
device that takes up hydrogen and releases it at a certain temperature.
- Calorimetry: infrared camera (military devp for missiles). Therefore, the 
reactor must be ablack body. Paint had to be developed that stays black at 
1200°C and was developed with the help of a company that produces paint for 
fighter engines.
- Convection energy was measured (with border pixels) and corrected for.
- All in all, Rossi was flowing, didn't have to think what to say, told an 
anecdote. „the hot cat is a war ship, not a cruise ship“. „I'm investing in it 
and I believe in this product“

By now the report is online: 
http://www.e-catworld.com/2012/09/high-temperature-e-cat-report-published/

LEONARDO engineer Flavio Fabiani spoke about security and controls, (made many 
jokes,) and left all questions to be answered by Rossi. Also Rossi's entourage 
from PROMETEON srl (Italian branch) didn't answer questions. It's up to the 
boss and will happen today:

- One Central Control Single Unit per ecat in a fat cat controls: (a) water 
inflow, (b) temp in exchanger (reactor), (c ) security valves, (d) pressure 
inside the reactor, (e) dryness of steam, (f) input voltage and amperage. The 
CCSUs supervise single modules and bring them down if they malfunction
- All CCSUs ae LAN connected and can be internet remote controlled
- A fat cat (MW1) has 90 modules, 3 of them sleeping. „sleeping modules“ will 
automatically turn on when another module turns off (eg when fault), 
stabilizing output

There may be flaws in my report.

Haiko

 

 