Here are the lab notes from the 03-18-2000 run.

Minutes  Tc  Tf Pin    Tc - Tr  Deg C/W Tr RUN 031800 MARCH 18, 2000
0 21.5 19.81 0 0.5 0 21
5 130.1 19.85 20 109.1 6.505 21 971V 0.021A
10 219.4 19.85 20 198.4 10.97 21 018V 0.019A
15 275.5 17.89 20 254.5 13.775 21 ADJ FILL PRESSURE
20 307.7 19.29 20 285.7 15.385 221085V 0.018A
25 326.3 19.93 20 304.3 16.315 22VERY STEADY GLOW
30 337.8 20 20 315.8 16.89 221062V 0.019A
35 342.1 19.99 20 319.1 17.105 231061V 0.019A
40 346.1 20.21 20 323.1 17.305 231056V 0.019A
45 346.4 20.22 20 323.4 17.32 231059V 0.019A
50 347.7 20.66 20 324.7 17.385 231059V 0.019A
55 349.7 20.98 20 328.7 17.485 211059V 0.018A
60 350.5 21.31 20 329.5 17.525 211059V 0.019A
65 351.3 21.62 20 330.3 17.565 211038V 0.019A
70 351.3 21.87 20 330.3 17.565 211040V 0.019A
75 351.3 21.96 20 329.3 17.565 22ADJ FILL PRESSURE Tc  FALLS
80 348.2 19.48 20 326.2 17.41 221113V 0.018A
85 350.5 19.71 20 328.5 17.525 221035V 0.019A
90 349.7 19.93 20 326.7 17.485 23INCR FILL TO 30.33 TORR
95 354.3 30.63 20 331.3 17.715 23Tc FIRST INCR THEN FALLS BACK
100 350.4 30.8 20 327.4 17.52 23 846V 0.024A
105 350.1 30.97 20 327.1 17.505 23REDUCE FILL TO 17.30 TORR
110 344.5 17.45 20 321.5 17.225 23Tc FALLING
115 344.1 17.51 20 321.1 17.205 23Tc LEVELING OFF
120 345.4 17.55 20 322.4 17.27 231264V 0.016A
125 345.3 17.77 20 322.3 17.265 231266V 0.016A
130 346.4 17.94 20 323.4 17.32 23HERE FILL TO 97.9 TORR
135 350.8 97.93 20 327.8 17.54 23 Tc RISING
140 351.4 98.1 20 327.4 17.57 24360V 0.056A
145 350.8 98.1 20 326.8 17.54 24 HERE REDUCE FILL TO 24.81
150 351.6 25.46 20 327.6 17.58 24360V 0.055A
155 350.8 25.74 20 326.8 17.54 24 HERE INCR Pin TO 30 WATTS
160 401.9 25.85 30 377.9 13.39 24
165 434.8 25.87 30 410.8 14.49 24CATHODE/SLEEVE AT BRIGHT YELLOW HEAT
170 450.2 25.94 30 426.2 15.00 24463V 0.065A
175 472.8 26.04 5 448.8 94.56 24469V 0.012A SUDDEN DROP IN TUBE CURRENT
180 480.3 26.2 5 456.3 96.06 24391V 0.013A VERY BRIGHT WHITE CATHODE GLOW
185 489.8 26.27 5 465.8 97.96 24395V 0.012A WOW!
190 498.8 26.35 5 474.8 99.76 24490V 0.011A
195 514.2 26.53 30 490.2 17.14 24398V 0.076A SUDDEN INCR IN TUBE CURRENT
200 500.3 26.54 30 476.3 16.67 24545V 0.053A HERE FILL TO 80 THEN PUMP TO 26.35
205 494.5 26.45 30 470.5 16.48 24 Pin JUMPING ABOUT 22-30 WATTS
210 488.1 26.7 30 464.1 16.27 24GLOW ELEC NOISE AFFECT Tc METERING
215 479.9 26.83 30 455.9 15.99 24VERY HARD KEEP Pin STEADY
220 499.3 26.92 30 475.3 16.64 24Tc INCREASING Pin INDICATE 24-30 VERY JUMPY
225 504.3 26.98 30 480.3 16.81 24T+ 225.5-TUBE VACUUM SEAL FAILED...END OF RUN THE QUESTION OF THE DAY: WHAT HAPPENED AT T+174 WHEN THE TUBE CURRENT FROM 65 mA TO 12 mA? THIS WAS APPROX TEN MINUTES AFTER Pin WAS INCREASED BY 10 WATTS FROM 20 TO 30 WATTS INPUT.
NOTHING WAS CHANGED WHEN THIS HAPPENED

----- Original Message ----- From: "Jones Beene" <[EMAIL PROTECTED]>
To: <[email protected]>
Sent: Wednesday, June 08, 2005 6:01 PM
Subject: Re: DoThe Emitted Electrons From Hot Tungsten Break The H-H Bond?


.........snip..........<<<

To quote Vince C. :  "

Indeed! When I was running a glow discharge in H2 + K, I had an 'event' that I can not explain. I had run this experiment probably a hundred times and had never seen what occurred. A run on March 18, 2000 at a 30 watt tube current was proceeding steady and normal when suddenly the wattage dropped to ~5 watts input and the temperature increased by over 400 C. in the next few minutes. Without going back and searching my lab notes I recall the voltage remained at about 300 dc and the current dropped way down. I guess this indicates that the tube impedance suddenly increased, but as to why, I don't have a clue.

And try as I might over the next year or so I was never able to replicate.

Regards,
Vince Cockeram
Las Vegas

One moral from that: Keep real good notes and datalog if possible !